Mean well 960w din rail power supply 48v/960W Three Phase Industrial DIN RAIL with PFC Function
USD $1 - $100 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
UL CE approved Meanwell 48V 60W Single Output Industrial DIN Rail Power Supply
Meanwell 48V 100W Single Output Industrial DIN Rail Power Supply/48v Industrial DIN Rail 100w
Meanwell single output Industrial slim din rail power supply EDR-75-24 75W 24V
Meanwell din rail DRA-60-24 60w 24v 2.5a industrial din rail power supply
MODEL | TDR-960-48 | |
OUTPUT | DC VOLTAGE | 48V |
RATED CURRENT | 20A | |
CURRENT RANGE | 0 ~ 20A | |
RATED POWER | 960W | |
RIPPLE&NOISE (max.) Note.2 | 250mVp-p | |
VOLTAGE ADJ. RANGE | 48~ 55V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.0% | |
SETUP, RISE TIME | 1000ms, 100ms / 400VAC 800ms, 100ms/500VAC at full load | |
HOLD UP TIME (Typ. | 12ms/400VAC 14ms / 500VAC at full load | |
INPUT
| VOLTAGE RANGE | Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDC |
POWER FACTOR (Typ.) | PF>0.88/400VAC PF 0.86/500VAC at full load | |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 94.5% | |
AC CURRENT (Typ.) | 2A/400VAC 4A/500VAC | |
INRUSH CURRENT (Typ.) | COLD START 60A | |
LEAKAGE CURRENT | <3.5mA / 530VAC | |
PROTECTION | OVER LOAD | 105 ~ 130% rated output power |
Protection type : Constant current limiting, unit will shut down after 3 sec. re-power on to recover | ||
OVER TEMPERATURE | 85°C± 5°C (TSW:detect on heatsink of power switch) | |
Protection type : Shut down o/p voltage, re-power on to recover after temperature goes down | ||
OVER VOLTAGE | 56~ 65V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
FUNCTION | DC OK REALY CONTACT RATINGS (max.) | 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load |
CURRENT SHARING | Please refer to function manual | |
ENVIRONMENT | WORKING TEMP. | -30~+70°C (Refer to derating curve) |
WORKING HUMIDITY | 20~95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | |
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL508 approved, IEC60950-1 CB approved by SIQ |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC | |
EMC EMISSION | Compliance to EN55022(CISPR22), Class B, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11,EN61000-6-2 (EN50082-2),EN61204-3, EN55024,heavy industry level, criteria A | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |
OTHERS | MTBF | 59.4K hrs min. MIL-HDBK-217F (25 ) |
DIMENSION | 110*125.2*150mm (W*H*D) | |
PACKING | 2.47Kg ; 6pcs/15.8Kg/1.47CUFT | |
NOTE | 1 All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2.. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5.Dual phase operation is allowed under certain derating to output load.Please refer to derating curves for details. 666.Installation clearances:40mm on top,20mm on the bottom,5mm on the left and right side are recommended when loaded permanently with full power.In case the adjacent device is a heat source ,15mmclearance is recommended |