Mean well 40W 15v Converter power supply 40w 15v
USD $1 - $10 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
ORDER NO. | SKA40C-15 | ||
OUTPUT | DC OUTPUT VOLTAGE | 15V | |
CURRENT RANGE | 0.26 ~ 2.67A | ||
RATED POWER | 40W | ||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | ||
LINE REGULATION Note.3 | ±0.5% | ||
LOAD REGULATION Note.4 | ±0.5% | ||
VOLTAGE ACCURACY | ±2.0% | ||
SWITCHING FREQUENCY | 200KHz typ. | ||
EXTERNAL CAPACITANCE LOAD (max.) | 1000uF | ||
EXTERNAL TRIM Adj. RANGE(Typ.) | ±10% | ||
INPUT | VOLTAGE RANGE | A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 75VDC | |
EFFICIENCY (Typ.) | 90% | ||
DC CURRENT | Full load | A: 3850mA B: 1900mA C: 1000mA | |
No load | A: 150mA B: 100mA C: 65mA | ||
FILTER | Pi network | ||
REMOTE CONTROL | Power ON : R.C ~ -Vin > 2.5VDC or open circuit ; Power OFF : R.C ~ -Vin < 0.5VDC or short | ||
PROTECTION | Fuse recommended | ||
PROTECTION (Note. 5) | OVER CURRENT | 110 ~ 180% rated output power | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||
SHORT CIRCUIT | All output equipped with short circuit | ||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 5Vo : 7V ~ 8.95V ; 12Vo : 15V ~ 19.2V ; 15Vo : 18V ~ 23.3V Protection type : Clamp by TVS diode | ||
ENVIRONMENT | WORKING TEMP. | -40~+80°C (Refer to output load derating curve) | |
WORKING HUMIDITY | 20 ~ 90%RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -55~+105°C, 10~95%RH | ||
TEMP. COEFFICIENT | 0.03%/°C (0~ 50°C) | ||
VIBRATION | 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes | ||
SAFETY & EMC | WITHSTAND VOLTAGE | I/P-O/P:1.5KVDC | |
ISOLATION RESISTANCE | I/P-O/P: 100M Ohms / 500VDC / 25°C/ 70% RH | ||
EMC EMISSION | Compliance to EN55022 Class A, FCC part 15 Class A | ||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A | ||
OTHERS | DIMENSION | 50.8*50.8*11.0 mm or 2"*2"*0.43" inch (L*W*H) | |
WEIGHT | 60g | ||
NOTE | 1. All parameters are specified at normal input, rated load, 25°C 70% RH ambient . 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 20% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds. |