MODEL | RSD-300B-24 | ||
OUTPUT | DC VOLTAGE | 24V | |
RATED CURRENT | 11.3A | ||
CURRENT RANGE | 0 ~ 11.3A | ||
RATED POWER | 271.2W | ||
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ||
LINE REGULATION | ±0.2% | ||
LOAD REGULATION | ±1.0% | ||
SETUP, RISE TIME | 800ms, 50ms at full load | ||
HOLD UP TIME (Typ.) | B/C- type comply with S1 level at full load, comply with S2 level at 70% load | ||
INPUT | VOLTAGE RANGE | CONTINUOUS | 16.8 ~ 31.2VDC |
1 SEC. | 14.4 ~ 33.6VDC | ||
EFFICIENCY (Typ.) | 90% | ||
DC CURRENT(Typ.) | 14.6A/24V | ||
INRUSH CURRENT (Typ.) | 45A/24VDC | ||
PROTECTION | OVER LOAD | 105% ~135% rated output power | |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 13.8 ~ 16.2V | ||
Protection type : Shut down o/p voltage, re-power on to recover | |||
OVER TEMPERATURE | B/C- type : 110°C±5°C(TSW1) detect on main power transformer | ||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | |||
ENVIRONMENT | WORKING TEMP. | -40~+55°C (no derating) ; +70°C@ 60% load by free air convection ; +70°C no derating with external base plate, TX class compliance | |
WORKING HUMIDITY | 5~95% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -40~+85°C, 5~95%RH | ||
TEMP. COEFFICIENT | ±0.03%/°C (0~55°C) | ||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373 | ||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Meet IEC60950-1(LVD) | |
WITHSTAND VOLTAGE | I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC | ||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||
EMC EMISSION | Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B | ||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A | ||
RAILWAY STANDARD | Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC | ||
Others | MTBF | 130.7K hrs min. MIL-HDBK-217F (25°C) | |
DIMENSION | 216*97*40mm (L*W*H) | ||
PACKING | 1.19Kg ; 12pcs/15.3Kg/1.12CUFT | ||
NOTE | 1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |