Mean well UL CE CB SD-100C-24 power convereter 100W 24V Converter
USD $1 - $100 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
MODEL | SD-100C-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATEDCURRENT | 4.2A | |
CURRENTRANGE | 0~4.2A | |
RATEDPOWER | 100.8W | |
RIPPLE&NOISE Note.2 | 150MVP-P | |
VOLTAGE ADJ.RANGE | 23 ~ 30VDC | |
VOLTAGE TOLERANCE | ±1.0% | |
LINEREGULATION | ±0.2% | |
LOADREGULATION | ±0.2% | |
SETUP.RISEHOLD.TIME | 2s, 50ms(only D mode) at full load | |
HOLD UP TIME (Typ.) | 20ms(only D mode) at full load | |
INPUT
| VOLTAGE RANGE | B:19 ~ 36VDC C:36 ~ 72VDC D:72 ~ 144VDC or 85 ~ 132VAC |
EFFICIENCY | 81% | |
DC CURRENT | 2.4A/48V | |
INRUSH CURRENT (Typ.) | D:18A/96VDC | |
LEAKAGE CURRENT | <0.75mA/120VAC(SD-100D) | |
PROTECTION
| OVER LOAD
| 105 ~135% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE
| 31.5 ~ 37.5V/10% load | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
ENVIRONMENT
| WORKING TEMP. | -10~+60°C (Refer to derating curve) |
WORKING HUMIDITY | -20~90%RH non-condensing | |
STORAGETEMP HUMIDITY | -20~+85°C, 10~95%RH | |
TEMPCOEFFICIENT | ±0.03%/°C(0~50°C) | |
VIBRATION | 10~500HZ,2G 10min/1cycle period for 60 min each along X,Y,Z axes | |
SAFETY & EMC
| SAFETY STANDARDS | IEC60950-1 CB approved by TUV (for D type only) |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH | |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A | |
OTHERS
| MTBF | 356.7K hrs min.(SD-100B) 355.5K hrs min.(SD-100C) 341.9K Hrs min.(SD-100D) MIL-HDBK-217F (25°C ) |
DIMENSION | 199*98*38mm (L*W*H) | |
PACKING | 0.65Kg; 20pcs/13.8Kg/0.8CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to .EMI testing of component power supplies.. |