Mean well TS-200-212 True Sine Wave Power transistor inverter 200W
USD $1 - $200 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
Meanwell Modified Sine Wave DC-AC Inverter with MPPT Solar Charger ISI-500-112 solar inverter
Meanwell Modified Sine Wave DC-AC Inverter ISI-500-124 solar grid inverter
Meanwell ISI-500-148 48V DC to 110VAC Modified Sine Wave Inverter
Meanwell Modified Sine Wave DC-AC solar invert 12V to 230V with MPPT Solar Charger
Meanwell Modified Sine Wave 24V DC to 230V AC inverter ISI-500-224 solar power inverter
Meanwell Modified Sine Wave 48V dc to 230v ac inverter ISI-500-248 inverter with charger
MODEL | TS-200-212 | |
OUTPUT | RATED POWER | 200W |
MAXIMUM OUTPUT POWER | 230W for 180 sec. / 300W for 10 sec. / surge power 400W for 30 cycles(typ.) | |
AC VOLTAGE | Factory setting set at 230VAC | |
200 / 220 / 230 / 240VAC selectable by setting button S.W | ||
FREQUENCY | 50 ±0.1Hz 50/60Hz selectable by setting button | |
WAVEFORM | True sine wave (THD<3%) at rated input voltage | |
AC REGULATION Note.1 | ±3.0% at rated input voltage | |
FRONT PANEL INDICATOR | Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal | |
INPUT
| BAT. VOLTAGE | 12V |
VOLTAGE RANGE (Typ.) Note.3 | 10.5 ~ 15VDC | |
DC CURRENT (Typ.) | 20A | |
NO LOAD CURRENT DRAW (Typ.) | 1.25A | |
OFF MODE CURRENT DRAW | ≤1mA | |
EFFICIENCY (Typ.) Note.1 | 86% | |
BATTERY TYPES | Open & sealed Lead Acid | |
BATTERY INPUT PROTECTION | FUSE | 30A*2 |
BAT. LOW ALARM | 11.3± 4% | |
BAT. LOW SHUTDOWN | 10.5± 4% | |
BAT. POLARITY | By internal fuse open | |
OUTPUTPROTECTION | OVER TEMPERATURE | 85°C ± 5°C |
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor | ||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |
OVER LOAD (Typ.) | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
GFCI PROCTECTION | None | |
FUNCTION | REMOTE CONTROL | Open : Normal work ; Short : Remote off |
ENVIRONMENT | WORKING TEMP. | -10~+40°C at 100% load +60°C at 50% load |
WORKING HUMIDITY | 20%~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -30~+70°C / -22~ +158 F, 10~95%RH | |
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | Design refer to UL458 |
LVD | EN60950-1 | |
WITHSTAND VOLTAGE | Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC | |
ISOLATION RESISTANCE | Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH | |
| EMC EMISSION | Compliance to FCC class A |
EMC IMMUNITY | None | |
OTHERS | MTBF | 106.2K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 205*158*59mm (L*W*H) | |
PACKING | 1.63Kg; 6pcs/10.8Kg/1.44CUFT | |
NOTE | 1.Efficiency & AC regulation is tested by 200W, linear load at 13V/26V/52V input voltage. 2.All parameters not specified above are measured at rated load, 25 of ambient temperature.
3.The tolerance of each voltage value by models is:112/212→± 0.5V;124/224 ±1V;148/248±2V |
hing power supply dual output switching power supply switching power supply 12v -12v