Mean Well 40W Industrial Desktop Adaptor Power Supply For Online Shopping
USD $1 - $50 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
ORDER NO. | GS40A09-P1J | |
OUTPUT | SAFETY MODEL NO. | GS40A09 |
DC VOLTAGE Note.2 | 9V | |
RATED CURRENT | 4.45A | |
CURRENT RANGE | 0 ~ 4.45A | |
RATED POWER | 40W | |
RIPPLE & NOISE (max.) Note.3 | 100mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±5.0% | |
LINE REGULATION Note.5 | ±1.0% | |
LOAD REGULATION | ±5.0% | |
SETUP, RISE TIME Note.7 | 1000ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load | |
HOLD UP TIME (Typ.) | 50ms / 230VAC 15ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 85% | |
AC CURRENT(Typ.) | 1A / 115VAC 0.5A / 230VAC | |
INRUSH CURRENT (max.) | 65A / 230VAC | |
LEAKAGE CURRENT(max.) | 0.75mA / 240VAC | |
PROTECTION | OVERLOAD | 110 ~ 150%rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 9.45 ~ 12.15V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
ENVIRONMENT | WORKING TEMP. | -30 ~ +60°C(Refer to "Derating Curve") |
WORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY&EMC (Note. 6) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms /500VDC/25°C/70% RH | |
EMC EMISSION | Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B, GB17625.1 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | |
OTHERS | MTBF | 711K hrs min. MIL-HDBK-217F(25°C) |
DIMENSION | 125*50*31.5mm (L*W*H) | |
PACKING | 0.28Kg; 40pcs/12.02Kg/1.05CUFT | |
CONNECTOR | PLUG | Standard type P1J: 2.1* 5.5* 11mm, tuning fork type, center positive for stock ; Other type available by customer requested |
CABLE | See page2; Other type available by customer requested | |
NOTE | 1.All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. 7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. |