3500W 13L chiller water cooled
USD $0.01 - $9,000 /Set
Min.Order:1 Set
Wuxi Guanya Refrigeration Tech Co., Ltd.
Description:
The whole system is a closed liquid circulation system with the expansion of container,expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60℃.
The cycle is closed,there is no oil mist at high temperature and no water vapor at low temperature;Wide working temperature range of heat transfer oil;The entire circulation system without use of mechanical and electric valve.
FEATURES:
1.Wide working temperature range with cooling and heating function,
temperature range:-25~200℃.
2.With 2pcs of LED display controller,can show the setting temperature&
actual value,and alarm value for overtemperature.
3.Efficient fast, simple topping up liquid.
4.Ensure fast cooling at high temperature and can acheive 200℃~-25℃
temperature control continuously.
5.The cycle system is closed,there is no oil mist and water vapor happend,so
as to assure the lab safety and heat transfer fluid lifetime.
6.Use copeland brand compressor,circulation pump,stable performance and
reliable quality.
7.Self-diagnosis function; freezer overload protection; high pressure switch,
overload relay, thermal protection device, liquid low level protection, high
temperature protection and temperature fault protection.
8.Use the same kind of heat conducting in the whole heating-cooling cycle
when control heat conducting medium temperature.
9.High-lift design and meet the long-distance transportation of heat
conducting medium.
Structure design
A fully closed piping design, high efficiency plate heat exchanger used to reduce the
demand for the thermal fluid utilization while providing the system to achieve the rapid
ups and downs in temperature.
Displays various information on the touch screen.
Process Control Schematic diagram
High repetative of tempeature control effect
Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.
Technical Parameters
Model | HRT-25N | HRT-35N | HRT-50N | HRT-70N | HRT-100N | HRT-150N | |
Temperature range℃ | -50℃~250℃ | -50℃~250℃ | -50℃~250℃ | -50℃~250℃ | -50℃~250℃ | -50℃~250℃ | |
Controller | PID adaptive controller | ||||||
Temp. control | Heat-conducting medium outlet temp. control | ||||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | ||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | ||||||
Temp. accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Heating power | 2500W | 3500W | 5500W | 7500W | 10000W | 15000W | |
Cooling capacity | 250℃ | 2000W | 3500W | 5500W | 7500W | 10000W | 15000W |
100℃ | 2000W | 3500W | 5000W | 7000W | 10000W | 15000W | |
20℃ | 2000W | 3500W | 5000W | 7000W | 10000W | 15000W | |
0℃ | 1800W | 3000W | 5000W | 7000W | 10000W | 15000W | |
-20℃ | 850W | 1500W | 2850W | 4200W | 6000W | 11000W | |
-40℃ | 250W | 450W | 900W | 1500W | 2000W | 3750W | |
Circulation pump | Max25L/min 1BAR | Max50L/min 1BAR | Max50L/min 1BAR | Max50L/min 1BAR | Max75L/min 1.5BAR | Max110L/min 1.5BAR | |
Compressor | Tecumseh | Copeland | Copeland | Copeland | Copeland | Copeland | |
Evaporator | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | |
Operation panel | Display setting temperature, medium outlet and return temperature; 7-inch Touch screen display | ||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||||
Refrigerant | R-404A | R-404A | R404A | R404A | R404A | R404A | |
Connection size | DN-15 | DN20 | DN20 | DN20 | DN20 | DN-20 | |
Connection size (air-cooled) | 400*600*1050 | 550*680*1450 | 550*680*1450 | 620*700*1450 | 700*700*1750 | 700*700*1750 | |
Weight (air-cooled) | 160kg | 185kg | 245kg | 285kg | 320kg | 360kg | |
Power | AC 220V 50HZ 4.5kW (max) | AC 380V 50HZ 6.5kW (max) | AC 380V 50HZ 9kW (max) | AC 380V 50HZ 12.5kW (max) | AC 380V 50HZ 16.5kW (max) | AC 380V 50HZ 24kW (max) | |
Case material | Cold rolled steel | ||||||
Optional | SUS304 case material | ||||||
Optional power | 220V 60HZ three-phase source, 440V~480V 60HZ three-phase source |
2008 The first generation of refrigeration and dynamic temperature control system.
2009 Developed the second generation of refrigeration and heating thermostat.
2010 Established WUXI GUANYA REFRIGERATION TECHNOLOGY CO., LTD.
2012 Single compressor having multiple circulation systems is applied SUNDI and LT series.
2014 Developed with large capacity of ultra-low temperature freezer
2016 low temperature freezer, plate freezer into the market