-25~200 degree lab contant temperature control chiller
-25~200 degree lab contant temperature control chiller
-25~200 degree lab contant temperature control chiller
-25~200 degree lab contant temperature control chiller
-25~200 degree lab contant temperature control chiller

-25~200 degree lab contant temperature control chiller

USD $1,000 - $10,000 /Set

Min.Order:1 Set

Supply Ability:
200 Set / Sets per Month
Port:
Shanghai

Quick Details View All >

Condition:
Brandnew
Type:
Air-Cooled
Place of Origin:
Jiangsu, China
Brand Name:
LNEYA
Model Number:
150KG
Cooling Capability(kw):
50HZ

Wuxi Guanya Refrigeration Tech Co., Ltd.

Business Type: Manufacturer,Trading Company
Wuxi Jiangsu China
Main Products: Dynamic Temperature Control Systems ,Chiller ,Freezer ,test chamber ,Refrigerated heating circulator

Product Details

-25~200 degree heating refrigeration machine       HR-25

 

Product Description

 

Description:

The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the  tank temperature is limited to 60℃.
The cycle is closed,there is no oil mist at high temperature and no water vapor at low temperature; Wide working temperature range of heat transfer oil; The entire circulation system without use of mechanical and electric valve.

FEATURES:

1.Wide working temperature range with cooling and heating function, temperature range: -20~200℃.
2.With 2pcs of LED display controller, can show the setting temperature & actual value, and alarm value for overtemperature.

3.Efficient fast, simple topping up liquid.
4.Ensure fast cooling at high temperature and can acheive 200℃ ~ -20℃ temperature control continuously.
5.The cycle system is closed, there is no oil mist and water vapor happend, so as to assure the lab safety and heat transfer fluid lifetime.
6.Use copeland brand compressor,circulation pump,stable performance and reliable quality.
7.Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
8.Use the same kind of heat conducting in the whole heating-cooling cycle when control heat conducting medium temperature.
9.High-lift design and meet the long-distance transportation of heat conducting medium.

 

 

Technical parameter

 

 

Technical Parameters:

 

Model

HR-25

HR-35

HR-50

HR-70

HR-100

HR-150

Temperature range ℃

-25℃~200℃

Controller

PID adaptive controller

Temp. control

Heat-conducting medium outlet temp. control

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium temperature feedback PT100        

Temp. accuracy

±0.5℃

±0.5℃

±0.5℃

±0.5℃

±0.5℃

±0.5℃

Heating power

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

Cooling

capacity

200℃

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

100℃

2.5kW

3.5kWW

5.5kW

7kW

10kW

15kW

20℃

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

-5℃

2kW

3 kW

4.5kW

6.6kW

8kW

12kW

-20℃

1kW

1.8kW

2.8kW

3.8kW

4.6kW

7kW

Circulation pump

Max25L/min

2BAR

Max35L/min

2BAR

Max35L/min

2BAR

Max35L/min

2BAR

Max50L/min

2BAR

Max50L/min

2BAR

Compressor

Copeland

Copeland

Copeland

Copeland

Copeland

Copeland

Evaporator

Plate heat exchanger

Operation panel

Display setting temperature and testing temperature; Touch key display

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,

thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.

Closed circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,

pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

Refrigerant

R-404A

Connection size

DN-15

DN20

DN20

DN20

DN20

DN-20

Connection size (air-cooled)

400*600*1050

500*680*1350

550*680*1450

550*680*1650

620*680*1550

750*750*1750

Weight (air-cooled)

115KG

135kg

160kg

205kg

250kg

280kg

Power

AC 220V 50HZ

4kW (max)

AC 380V 50HZ

6kW (max)

AC 380V 50HZ

8kW (max)

AC 380V 50HZ

11kW (max)

AC 380V 50HZ

14kW (max)

AC 380V 50HZ

21kW (max)

Case material

Cold rolled steel

Optional

Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

Optional

SUS304 case material

Optional power

220V 60HZ three-phase, 440V~480V 60HZ three-phase

 

Company Information

Development history

2006 Start production of refrigeration and heating system .

 

2008  The first generation of refrigeration and dynamic temperature control system.

 

2009 Developed the second generation of refrigeration and heating thermostat.

 

2010 Established WUXI GUANYA REFRIGERATION TECHNOLOGY CO., LTD.

 

2012 Single compressor having multiple circulation systems is applied SUNDI and LT series.

 

2014  Developed with large capacity of ultra-low temperature freezer

 

2016   low temperature freezer, plate freezer into the market

 

 

Factory online visiting

 

Please kindly copy  /wxgy360/wxgy360_1.html  


Certifications

 

 

FAQ

-25~200 degree lab contant temperature control chiller

 

contact

-25~200 degree lab contant temperature control chiller 

 

Contact Supplier

Ms. Lisa Li engineer Chat Now
Telephone
0086-510-82321181
Mobile
0086-17715697019
Fax
0086-510-82303782
Address
No.10, Zhenfa No.1 Road, New district, Wuxi, Jiangsu, China Wuxi,Jiangsu

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Machinery > Refrigeration & Heat Exchange Equipment > Industrial Chiller