Industrial water cooling chiller with 60KW cooling capacity
USD $1,000 - $20,000 /Set
Min.Order:1 Set
Wuxi Guanya Refrigeration Tech Co., Ltd.
Dynamic temperature control machine
-10~200 degree SUNDI-1A60W
Typical Applications
Reactor Systems Autoclaves
Pilot Systems
Double wall reactors
Advanced-Flow Reactors
Material Testing
Semiconductor Industry
Vacuum Chambers
Advantages & Functions
Working temperatures from -100℃ to +350℃
Intelligent temp. control
Max. process stability
Plate heat exchager
Closed system
Touch screen display
Warning and safety functions
Rapid cooling
Magnetic drive pump
Structure design
A fully closed piping design, high efficiency plate heat exchanger used to reduce the
demand for the thermal fluid utilization while providing the system to achieve the rapid
ups and downs in temperature.
Displays various information on the touch screen.
Process Control Schematic diagram
High repetative of tempeature control effect
Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.
Technical Parameters:
Model | SUNDI-1A25W | SUNDI-1A38W | SUNDI-1A60W | SUNDI-1A95W | SUNDI-1A130W | |
Temperature range ℃ | -10℃~200℃ | |||||
Controller | Feed forward PID +Our special dynamic control calculation, PLC controller | |||||
Temp. control | Option: process temperature control or jacket oil temperature control | |||||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | |||||
Program Editor | 20 programs, each program can edit 45 steps. | |||||
Communication | MODBUS RTU Protocol, RS 485 Interface | |||||
Temperature feedback | Heat-conducting medium feedback PT100, (oil outlet temperature, oil inlet temperature and heater temperature), Three temperature measuring points. | |||||
Process Temperature feedback | Raw material process feedback PT100 or 4~20mA input (optional) | |||||
Temp. accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | |
Cooling capacity | 200℃ | 25kW | 38kW | 60kW | 95kW | 130kW |
0℃ | 25kW | 38kW | 60kW | 95kW | 130kW | |
-10℃ | 15kW | 22.8kW | 36kW | 57kW | 78kW | |
Circulation pump | Max150L/min 2.5BAR | Max250L/min 2.5BAR | Max250L/min 2.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | |
Compressor | Copeland | Copeland | Copeland | Copeland | Copeland | |
Evaporator | Shell and-tube evaporator | |||||
Expansion valve | Emerson | |||||
Operation panel | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | |||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | |||||
Closed | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | |||||
Refrigerant | R-410A | |||||
Connection size | DN25 PN10 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN40 PN10 | |
Water-cooled type W (cooling water at 30℃) | 8m³/h 1.5bar~4bar | 10m³/h 1.5bar~4bar | 15m³/h 1.5bar~4bar | 20m³/h 1.5bar~4bar | 28m³/h 1.5bar~4bar | |
Dimension | 1250*700*1500 | 1500*800*1600 | 1800*800*1650 | 2000*1000*1650 | 2300*1250*1750 | |
Weight | 640kg | 900kg | 1150kg | 1400kg | 1700kg | |
Power | AC 380V 50HZ 32kW (max) | AC 380V 50HZ 48kW (max) | AC 380V 50HZ 75kW (max) | AC 380V 50HZ 125kW (max) | AC 380V 50HZ 155kW (max) | |
Case material | SUS 304 | SUS 304 | SUS 304 | SUS 304 | SUS 304 | |
Optional | Optional Ethernet interface, configure the computer operating software | |||||
Optional power | 440V~480V 60HZ three-phase source |