Low temperature cooling Chiller of constant temperature control
USD $1,000 - $50,000 /Set
Min.Order:1 Set
Wuxi Guanya Refrigeration Tech Co., Ltd.
Dynamic Temperature Control systems
Cooling And Heating Temperature Control systems
Process heat transfer solutions applied to reactor
Typical Applications
Reactor Systems Autoclaves
Pilot Systems
Double wall reactors
Advanced-Flow Reactors
Material Testing
Semiconductor Industry
Vacuum Chambers
Advantages & Functions
Working temperatures from -100℃ to +350℃
Intelligent temp. control
Max. process stability
Plate heat exchager
Closed system
Touch screen display
Warning and safety functions
Rapid cooling
Magnetic drive pump
Structure design
A fully closed piping design, high efficiency plate heat exchanger used to reduce the
demand for the thermal fluid utilization while providing the system to achieve the rapid
ups and downs in temperature.
Displays various information on the touch screen.
Process Control Schematic diagram
High repetative of tempeature control effect
Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.
Technical Parameters:
Model | SUNDI-625W
| SUNDI-635WN SUNDI-635N | SUNDI-655W SUNDI-655 | SUNDI-675W SUNDI-675 | SUNDI-6A10W SUNDI-6A10 | SUNDI-6A15W
| |
Temperature range ℃ | -60℃~200℃ | -60℃~200℃ | -60℃~200℃ | -60℃~200℃ | -60℃~200℃ | -60℃~200℃ | |
Control Mode | Feed forward PID + Our special dynamic control calculation, PLC controller | ||||||
Temp. control | Option: process temperature control or jacket oil temperature control | ||||||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | ||||||
Program Editor | 20 programs, each program can edit 45 steps. | ||||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | ||||||
Temperature feedback | Heat-conducting medium: PT100 Raw material process: PT100 | ||||||
Temp. accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | |
Heating power | 2500W | 3500W | 5500W | 7500W | 10000W | 15000W | |
Cooling capacity | 200℃ | 2500W | 3500W | 5500W | 7500W | 10000W | 15000W |
100℃ | 2500W | 3500W | 5500W | 7500W | 10000W | 15000W | |
20℃ | 2500W | 3500W | 5500W | 7500W | 10000W | 15000W | |
0℃ | 2500W | 3500W | 5500W | 7500W | 10000W | 15000W | |
-20℃ | 2000W | 3000W | 4850W | 6000W | 8200W | 12000W | |
-40℃ | 950W | 1450W | 2300W | 3100W | 4800W | 7750W | |
-55℃ | 250W | 500W | 750W | 900W | 1500W | 2.8kW | |
Circulation pump | Max20L/min 2BAR | Max20L/min 2BAR | Max35L/min 2BAR | Max50L/min 2.5BAR | Max50L/min 2.5BAR | Max110L/min 2.5BAR | |
Compressor | Copeland | Copeland | Copeland | Copeland | Copeland | Copeland | |
Expansion valve | Danfoss | Danfoss | Danfoss | Danfoss | Danfoss | Danfoss | |
Oil separator | Emerson | Emerson | Emerson | Emerson | Emerson | Emerson | |
Evaporator | KAORI Plate heat exchanger | KAORI Plate heat exchanger | |||||
Operation Panel | 7-inch color touch screen controller, temperature curve record, data export to excel format. | ||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||||
Refrigerant | R-404A R23 | R-404A R23 | R404A R23 | R404A R23 | R404A R23 | R404A R23 | |
Connection size | DN-15 or M24*1.5 | DN15 or M30*1.5 | DN20 or M30*1.5 | DN20 or M30*1.5 | DN20 or M30*1.5 | DN-25 M38*1.5 | |
Water-cooled type W (cooling water at 20℃) | 900L/H 1.5bar~4bar | 1200L/H 1.5bar~4bar | 1800L/H 1.5bar~4bar | 2100L/H 1.5bar~4bar | 3000L/H 1.5bar~4bar | 4000L/H 1.5bar~4bar | |
Dimension | water-cooled | 400*600*1050 | 550*680*1450 | 600*700*1650 | 600*700*1650 | 600*700*1650 | 700*700*1650 |
air-cooled |
| 550*680*1450 | 620*680*1450 | 620*700*1550 | 750*750*1750 |
| |
Weight | water-cooled | 170kg | 185kg | 265kg | 305kg | 340kg | 380kg |
| air-cooled |
| 225kg | 300kg | 340kg | 380kg |
|
Power | AC 220V 50HZ 5kW (max) | AC 380V 50HZ 7.5kW (max) | AC 380V 50HZ 10kW (max) | AC 380V 50HZ 14kW (max) | AC 380V 50HZ 18kW (max) | AC 380V 50HZ 26kW (max) | |
Case material | SUS 304 | SUS 304 | SUS 304 | SUS 304 | SUS304 | SUS304 | |
Optional | Optional Ethernet interface, configure PC operating software | ||||||
Optional | Optional outside touch screen display controller (separated), the communication line distance is 10 meter. | ||||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Model | SUNDI-6A25W | SUNDI-6A38W | SUNDI-6A60W | SUNDI-6A95W | SUNDI-6A130W | |
Temperature range ℃ | -60℃~250℃ | |||||
Controller | Feed forward PID +Our special dynamic control calculation, PLC controller | |||||
Communication | MODBUS RTU Protocol, RS 485 Interface | |||||
Temp. control | Process temperature control mode | |||||
Program Editor | 20 programs, each program can edit 45 steps. | |||||
Temperature feedback | Heat-conducting medium feedback PT100, (oil outlet temperature, oil inlet temperature and heater temperature), Three temperature measuring points. | |||||
Process Temperature feedback | Raw material process feedback PT100 or 4~20mA input (optional) | |||||
Temp. accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | |
Heating power | 25kW | 38kW | 60kW | 95kW | 130kW | |
Cooling capacity
| 250℃ | 25kW | 38kW | 60kW | 95kW | 130kW |
100℃ | 25kW | 38kW | 60kW | 95kW | 130kW | |
20℃ | 25kW | 38kW | 60kW | 95kW | 130kW | |
0℃ | 25kW | 38kW | 60kW | 95kW | 130kW | |
-20℃ | 25kW | 38kW | 56kW | 80kW | 90kW | |
-40℃ | 18kW | 22kW | 30kW | 45kW | 56kW | |
-55℃ | 6kW | 7.5kW | 11kW | 15kW | 19kW | |
Circulation pump | Max110L/min 2.5BAR | Max150L/min 2.5BAR | Max250L/min 2.5BAR | Max250L/min 2.5BAR | Max250L/min 2.5BAR | |
Compressor | Copeland | Copeland | Copeland | Bock | Bock | |
Evaporator | KAORI Plate heat exchanger | |||||
Oil separator | Emerson | |||||
Expansion valve | Emerson | |||||
Operation panel | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | |||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | |||||
Closed | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | |||||
Refrigerant | R-404A R23 mixed Refrigerant | |||||
Connection size | DN25 PN10 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN40 PN10 | |
Water-cooled type W (cooling water at 30℃) | 8.5m³/h 1.5bar~4bar | 14m³/h 1.5bar~4bar | 20m³/h 1.5bar~4bar | 29m³/h 1.5bar~4bar | 38m³/h 1.5bar~4bar | |
water-cooled condenser | Shell and tube exchanger(standard) | |||||
Dimension | 1500*1000*1750 | 1800*1200*1750 | 2050*1450*1750 | 2300*1450*1750 | 2750*1600*1850 | |
Weight | 980kg | 1150kg | 1380kg | 1750kg | 2280kg | |
Power | AC 380V 50HZ 38kW (max) | AC380V 50HZ 58kW (max) | AC 380V 50HZ 85kW (max) | AC 380V 50HZ 30kW (max) | AC 380V 50HZ 180kW (max) | |
Case material | SUS 304 | SUS 304 | SUS 304 | SUS 304 | SUS 304 | |
Optional | Optional Ethernet interface , configure the computer operating software | |||||
Optional | Water condenser use plate heat exchanger (request for high quality water) | |||||
Optional power | 440V~480V 60HZ three-phase |