High-Precision heating circulator heating chiller with large heating capacity UC-A2520
USD $10 - $10,000 /Piece
Min.Order:1 Piece
Wuxi Guanya Refrigeration Tech Co., Ltd.
Industrial using high temperatue control machine heating circulator UC-A1520
50~300 degree Industrial heating thermostat Heating circulators UC-A2530
Energy saving lab using closed system mini heating circulator UC-5020
50 degree to 200 degree Heating circulators lab heating box UC-A520
50~ 200 degree Heating circulators temperature control machine for industrial production UC-A6030
50~300 degree high temperature thermostats Heating circulators UC-A3830
Heating Circulator UC-A2520
oil heater electric heat high temperature circulators Heating circulators high temp thermostat UC series 50~ 300 degree
high temp heating thermostat high temp thermostat high heating thermostatic high heating circulators
heating and cooling load high heating capacity, high temperature heater, thermostate heater, Cooling heating Agent
Description:
The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic,
and did not participate in liquid circulation, only mechanical connection, regardless of the temperature of liquid circulation is a high-temperature circumstances, the expansion of the medium container less than 60 degrees.
FEATURES :
1.The liquid circulation system is sealed and it does not produce the oil mist, which can extend the using life of heat-conducting oil and reduce the risk of accidents
2.PT100 temperature sensor can adjust the temperature
3. The system for precisely controlling the temperature of applications and processes of jacketed reactor.
4. The system is a closed liquid circulation system with the expansion of container
5. Without the need to change media operation during the operation
6.Multi-alarming devices (over-temperature alarm, sensor alarm, high pressure alarm, overheat alarm compressor)
ADVANTAGES:
1.Small space required
2.Low filling Volume
3.High pump Capacity
4.Rapid&efficient filling of the complete application with venting
5.+60 degree max.expansion tank temperature
6.Simple operation
7.High level of safety through constant monitoring
Technical Parameters:
Model | UC-A1520 | UC-A2520 | UC-A3820 | UC-A6020 | UC-A9520 | UC-A13020 | UC-A20020 | |
Temperature range ℃ | 50℃~200℃ | |||||||
Controller | PID adaptive controller | |||||||
Temp. Control optional | Heat-conducting medium outlet temp. control | |||||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | |||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | |||||||
Temp. accuracy | ±0.5℃ | ±0.5℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±2℃ | |
Heating power | 15kW | 25kW | 38kW | 60kW Divide to two groups heating | 95kW Divide to three groups heating | 130kW Divide to three groups heating | 200kW Divide to four groups heating | |
Heater can be divided into groups. When the testing temperature reached to (setting temperature -5℃), it can close the most of heating duty and leave the next group to be PID fuzzy control. | ||||||||
Cooling capacity | 300℃ |
|
|
|
|
|
|
|
200℃ | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW | |
100℃ | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | 160kW | |
65℃ | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | 64kW | |
| There is a heat exchanger in the system and it needs water to cool. Open the water valve automatically according to demand. | |||||||
Circulation pump | Max50L/min 2.5BAR | Max110L/min 2.5BAR | Max110L/min 2.5BAR | Max250L/min 2.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | Max400L/min 2.5BAR | |
Expansion tank volume | 35L | 65L | 90L | 160L | 240L | 300L | 500L | |
Heater | Orient electric heater | |||||||
Independent temperature limiter | LNEYA | |||||||
Cooler | Plate heat exchanger | |||||||
Operation panel | Display setting temperature and testing temperature; Touch screen display | |||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload | |||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | |||||||
Connection size | DN-25 | DN25 | DN25 | DN40 | DN40 | DN-50 | DN-50 | |
Dimension | 600*600*1250 | 600*600*1250 | 1200*750*1100 | 1200*750*1100 | 1400*750*1300 | 1400*750*1300 | 1500*850*1450 | |
Weight | 100kg | 130kg | 170kg | 285kg | 318kg | 450kg | 685kg | |
Power | AC380V 50HZ 15.7kW (max) | AC380V 50HZ 26.5kW (max) | AC380V 50HZ 39.5k (max) | AC380V 50HZ 63kW (max) | AC380V 50HZ 98kW (max) | AC380V 50HZ 135.5kW (max) | AC380V 50HZ 206kW (max) | |
Case material | Cold rolled steel painting | |||||||
Optional | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | |||||||
Optional | SUS 304 SUS 304 case material | |||||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Wuxi Guanya Refrigeration Technology Co., Ltd. Specialized in rerfigeration equipment, ultra-low temperature freezer, cooling and heating temperature control system, heating circulation system, explosion-proof electric equipment. Automatic integrated disparate control system, laboratory apparatus. We are the technology leader for high precision thermoregulation solutions in Research and Development Industry. Our products ensure precise temperature control throughout the whole world in laboratories, pilot plants and production processes. Our product range offers temperature control solutions for applications from -152 to +350℃.
We make market and user need oriented products, focusing on science and technology applying international advanced technology, endlessly get rid of the stale and bring forward the fresh following the market step & meet market demand. The company always insists on standardised management in accordance with ISO9001-2008 international quality certification requirement from product design, purchase and selection of components, to production process flow, packaging and transportation etc, try to keep improving products, and keep reasonable price and satisfactory service.
Development history
In 2006 Start production of refrigeration and heating system equipments.
In 2007 Developed the first generation of refrigeration and heating thermostat and establish the LNEYA CO., LTD.
In 2008 Developed the first generation of refrigeration and dynamic temperature control system.
In 2009 Developed the second generation of refrigeration and heating thermostat.
In 2010 Established WUXI GUANYA REFRIGERATION TECHNOLOGY CO., LTD.
Developed the second generation of refrigeration and heating dynamic temperature control system.
Developed the refrigeration and heating dynamic temperature control system & low temperature freezer for industry use.
In 2011 Developed new technology with single compressor having multiple circulation systems (can reach to -80 degree with single compressor)
Upgraded the second generation of refrigeration and heating dynamic temperature control system.
In 2012 Single compressor having multiple circulation systems is applied in production of SUNDI-4, SUNDI-5, SUNDI-6, and SUNDI-7, SUNDI-8 and LT series.
Upgraded the second generation of refrigeration and heating dynamic temperature control system for the second time and developing the third generation of refrigeration and heating dynamic temperature control system.
In 2013 Developed new product one operating multi refrigeration and heating temperature control system(the third generation of refrigeration and heating dynamic temperature control system).At the same time testing the large capacity of ultra-low temperature freezer.
In 2014 Developed with large capacity of ultra-low temperature freezer which used for industrial production,new goods will be research.And it will be launched in the market soon........