1000L industrial ultra low temperature freezer
USD $1,000 - $20,000 /Set
Min.Order:1 Set
Wuxi Guanya Refrigeration Tech Co., Ltd.
Description:
♦ Microcomputer control, cascade temperature controller, digital temperature display, the regulation of unit 0.1℃, inside the temperature range -20 ℃ ~ -125 ℃ adjustable.
♦ Multi-safety protection, more reliable operation.
♦ France TECUMSEH compressor, Germany DANFOSS compressor, EMERSON compressor, automatic cascade refrigeration technology.
♦ With self-diagnosis function, freezer overload protection, high pressure switches, overload relays, thermal protection device and other security functions, and fully guarantee the use of safety.
♦ Three sealed mold layer of insulation, Extra-thick high-density polyurethane foam insulation layer,
the effect of good insulation;Inline vacuum insulation panels.
♦ Human design, more convenient and flexible.
♦ Suitable for mechanical producing plant use.
♦ Large condenser design, fully guaranteed plant environment cooling effect.
♦ Wide volume ratio design, large load capacity design.
♦ Can be set to open compressors and compressor off temperature.
♦ Fault alarm (over-temperature alarm, sensor alarm, high alarm, overheat alarm compressor.
♦ Delay boot protection.
So grounding components safely.
♦ LED display, clear display inside temperature and the desire temperature; can set the
overtemperature alarm and the inside temperature, fault prompt functions.
♦ Non-standard sizes can be customized, Ultra-low temperature freezer (can be produced
within -100℃ 100 cubic).
♦ Optional equipments: PLC controller, color touch-screen, temperature recorder etc.
Application:
It is mainly used in industrial refrigerating treatment, so that the matrix of the metal structure to generate a uniform, fine and dispersed precipitation. The precipitation of carbide will improve the abrasion resistance, friction performance and increase hardness of metal. The carbide is the ideal alternative to liquid nitrogen.
For the copper sleeve and bearings contracting, it is widely used in precise mechanical assembly. Applied to large scale equipment(cars, large engineering machineries, aircraft component, Aerospace equipment parts, Military equipment parts etc.) lower temperature test.
As the refrigerating treatment equipment is produced specially,
please provide us the following information:
1. Maximum Loading.
2. Liner Size:L/W/H
3. Full load cooling to the time of the target value.
Technical Parameters
Model | GX-8028N | GX-8050N | GX-80A10N | GY-8028N | GY-8050N | GY-8080N | GY-80A16N |
Volume | 280L | 500L | 1000L | 280L | 500L | 800L | 1600L |
Inner dimension | 610*600*760 | 800*735*850 | 1000*1000*1000 | 800*600*600 | 1200*650*650 | 1350*800*750 | 2000*900*900 |
Type | (Vertical) | (Chest/Horizontal) | |||||
Capacibility carrying | 150KG | 220KG | 300KG | 150KG | 220KG | 300KG | 650KG |
Designed bearing capacity is two times of the standard one, (refrigeration system is designed according to the standard capacity, when target artifact weight is greater than the standard capacity, the cooling rate will decrease) | |||||||
Temp. range | -80℃~60℃ | -80℃~60℃ | -80℃~60℃ | -80℃~60℃ | -80℃~60℃ | -80℃~60℃ | -80℃~60℃ |
Cooling capacity at -75℃ | 1kw | 1.5kw | 2.5kw | 1kw | 1.5kw | 2.5kw | 4kw |
Temp. accuracy | ±2℃ | ±2℃ | ±2℃ | ±2℃ | ±2℃ | ±2℃ | ±2℃ |
Heating power | 2kw | 3kw | 5kw | 2kw | 3kw | 5kw | 8kw |
Nickel-chromium alloy electric heating heater, the controller has double safety protection, with independent temperature limiter protection. | |||||||
Cooling rate | (ambient temperature of 25 degrees, no-load, from 60 degrees to -60 degrees about 1 hour).;cooling rate will be a little different for temperature changes. | ||||||
Controller | ASET multifunctional controller | ||||||
Operation panel | 7-inch color touch screen , display set temperature, measured temperature.
| ||||||
Temp. record | Temperature curve and fault record , U-disk data export, excel format.
| ||||||
Inside circulating air | 1650 m³/h | 2100 m³/h | 2750 m³/h | 2100 m³/h | 2750 m³/h | 3500 m³/h | 6000 m³/h |
When it is open, the internal circulation fan automatically turns off. The touch screen displays open state. | |||||||
Compressor | Emerson Copeland , adopt cascade refrigeration technology | ||||||
Intermediate heat exchanger | KAORI Plate heat exchanger | ||||||
Dry filter | Emerson | ||||||
Expansion valve | Electronic expansion valve | ||||||
Evaporator | Copper-tube with aluminum-fin | ||||||
Cooling Type | Air-cooled with water-cooled auxiliary functions (Ensure good cooling capacity when temp. above 30 degree) | ||||||
Means of insulation | Polyurethane foam insulation, thermal insulation layer 125 mm, with embedded FIR boards | ||||||
Safety Protection | Self-diagnosis function;Phase sequence phase failure protection; leakage protector; cooling unit overload protection; high and low pressure switch, overload relay, thermal protection device, high temperature protection and temperature fault protection. | ||||||
Case material | Outside is cold rolled steel painting, internal is SUS304 wire drawing board. | ||||||
Refrigerant | R404A R23 | ||||||
Dimension | 1150*1150*1850 | 1350*1300*1850 | 1550*1500*2100 | 2200*1150*1150 | 2700*1200*1200 | 2900*1300*1250 | 3700*1400*1350 |
Power 380V 50HZ | 7KW MAX | 11.5KW MAX | 15KW MAX | 7KW MAX | 11.5KW MAX | 15KW MAX | 21KW MAX |
Weight | 400kg | 500kg | 690kg | 415kg | 525kg | 710kg | 840kg |
Optional
| High temperature reaches 150℃ and temperature accuracy is ±0.5℃;the input power will be changed(When select this model, the thickness of thermal insulation layer will be 150mm,thermal insulation material will be silicate and vacuum plate) | ||||||
Optional | Closed circulating oil heating system, no direct electric heating element inside the box, suitable for flammable products test | ||||||
Optional | Temp. accuracy ±0.5℃ | ||||||
Optional | Cooling and heating with program controlled, meet cold treatment process requirements(can set 5 programs, each program can edit 45 steps.) | ||||||
Optional | Interior door, reduce cooling capacity lost when pick small workpieces (temperature below 60 degree optional) | ||||||
Optional | Outside SUS304 wire drawing board case | ||||||
Optional | Diameter 50mm cable hole | ||||||
Optional | Electric heating vacuum glass observation window (with lighting) 200mm*300mm | ||||||
Optional | Low temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at low temperature for long time even the door is open and close frequently) |
2008 The first generation of refrigeration and dynamic temperature control system.
2009 Developed the second generation of refrigeration and heating thermostat.
2010 Established WUXI GUANYA REFRIGERATION TECHNOLOGY CO., LTD.
2012 Single compressor having multiple circulation systems is applied SUNDI and LT series.
2014 Developed with large capacity of ultra-low temperature freezer
2016 low temperature freezer, plate freezer into the market