PT-2770 (AC/DC,20KHz,10A~1500Ap-p)DC current sensor
Negotiable /Set
Min.Order:1 Set
Guangzhou Dekem Electronic Co., Ltd.
PT-2770 AC/DC current probe(Hall effect,1500A)
Product Introduction | |
Product Name: | PT-2770(20KHz,2A-1500Ap-p)current clamp |
Short Description: | PT-2770 DC-20KHZ AC/DC current probe |
Model Number | PT-2770 | ||||
Range | 50mV/A | 500mV/A | |||
Current range | DC:0A~50A AC:10A~150Ap-p | DC:50A~500A AC:150A~1500Ap-p | |||
Output signal error | 3%±5mV | 1500A:max.4% | |||
Bandwidth(-3dB) | DC~20kHz | ||||
Phase shift | DC~65Hz<1.5° | DC~65Hz:<1° | |||
Load impedance | ≥1MΩ and ≤100pF | ||||
Impedance | 0.01Ω | ||||
Noise | 5mV | ||||
Switching rate | 0.3V/μS | 20mV/μs | |||
Rise time | 2.3μs | ||||
Measuring condition | 23℃±5℃,20~75RH, Sinusoidal frequency 48~65Hz,external magnetic field <40A/m No load flow nearby,center testing sample, load impedance1MΩ | ||||
Operating voltage | Max.600Vrms | ||||
CMRR | Max.600Vrms | ||||
Battery | 9V | ||||
Low battery indicator | with green LED light when >6.5V | ||||
Overload indicator | Red LED light indicates the over measuring current, change the range | ||||
Mechanical Specifications | |||||
Operating temperature | 0~+50℃ | ||||
Storage temperature | -3~+80℃ | ||||
Temperature influence | Every 10℃,<0.2% | ||||
Operating relative humidity | +10℃~+30℃:85±5% relative humidity(non-condensing ) +40℃~+50℃:45±5%relative humidity(non-condensing ) | ||||
Operating height | 0~2000m | ||||
Max clam size | Diameter 10.3mm | ||||
Dimension | 231*36*67mm | ||||
Weight | 310g(not including battery) | ||||
Output | 2 meters of coaxial cable, with insulation BNC connector jack at the end |