XINFU Isothermal Titration Calorimetry
Negotiable
Min.Order:1
Zhengzhou Prominent Technology Co., Ltd.
GC106 Calorimeter is new developed model based on ZDHW-5 Calorimeter.
General Introduction of Isothermal Titration Calorimetry
Calorimeter calorimeter system, in addition to the water absorbs heat, the oxygen bomb, inner tube, thermometer and stirrer, and this will absorb heat, and absorbing their situation is different, more complex variety of factors, it is impossible to rely on a simple mathematical calculations to obtain, but to use the reference material of known calorific value such as benzoic acid to the actual calibration of the system temperature is increased by the amount of heat to be absorbed heat 1 ℃, which is calibrated out of the heat capacity of the calorimeter.
Under High Pressure Oxygen Condition:
Put samples in hot-corrosion-resistant metal crucible.
Put this crucible in oxygen bomb and seal it.
Charge oxygen in the bomb until the pressure reach 3.0Mpa
Put oxygen bomb in and turn on the calorimeter, burn the sample.
The heat will pass to the water in cylinder.
Calorimeter can calculate the calorific value of samples according to measure the water temperature, cylinder and bomb.
Features of GC106
The instrument is the use of monolithic microcomputer development of multifunctional heat measuring instruments, mainly for solid and liquid fuel, such as coal, oil, food, wood, garbage, coal, coke and other substances - Determination of calorific value. The system runs on Windows98 and above systems, into the machine interaction, that is used to. The software uses an object-oriented programming method, modular management technology, multi-task operation, the use of advanced serial communication technology, integrated system control and data management, good compatibility, ease of maintenance, to overcome the drawbacks of the computer interface board quit, with a wide range of adaptability, and effective use of scientific algorithms, data, high precision, stable and reliable system.
Working Principle of Isothermal Titration Calorimetry
Inner cylinder is also made of stainless steel, the cross section is oval. We special processed the surface to reduce the heat radiation and heat exchange. There is stirrer and thermometer hold designed on the top cover. Operator stick the temperature detector in the hole to test the temperature.
Standard Reference
ASTM E711-87(2004): Standard Test Method for Gross Calorific Value of Refuse-Derived Fuel by the Bomb Calorimeter (Withdrawn 2004) ASTM D3180 - 1: Standard Practice for Calculating Coal and Coke Analyses from As-Determined to Different Bases ASTM E955 - 88(2009)e1: Standard Test Method for Thermal Characteristics of Refuse-Derived Fuel Macrosamples ASTM D3172 - 13: Standard Practice for Proximate Analysis of Coal and Coke
Main Specification