Double Channel Medical Syringe pump MSLIS02
Double Channel Medical Syringe pump MSLIS02
Double Channel Medical Syringe pump MSLIS02
Double Channel Medical Syringe pump MSLIS02

Double Channel Medical Syringe pump MSLIS02

Negotiable /Set

Min.Order:1 Set

Supply Ability:
300 Set / Sets per Month
Port:
Guangzhou
Payment Terms:
T/T L/C Credit Card PayPal

Quick Details View All >

Properties:
Other, Injection & Puncture Instrument
Brand Name:
MSL
Model Number:
MSLIS02
Place of Origin:
Guangdong, China

Guangzhou Medsinglong Medical Equipment Co., Ltd.

Business Type: Manufacturer,Distributor/Wholesaler
Guangzhou Guangdong China
Main Products: Ultrasound ,Dental chair ,x-ray machine & accessories ,Blood analyzer ,Veterinary equipment

Product Details

Double Channel Medical Syringe pump MSLIS02
                

 

Double channel syringe pump MSLIS02

Double Channel Medical Syringe pump MSLIS02


 

Features & Functions of the Syringe pump MSLIS02 :

1. Three working modes: rate mode, time-volume mode, dosage-weight mode.

 

2. Unique Human Voice Alarm system and accurate injection rate make the injection process safer and more reliable.

 

3. Have store many brands syringes, automatically calibration and compatible with any brand syringes 

 

4. Large LCD screen displays working status.

 

5. KVO and Bolus functions.

 

6. IV infusion pump.

 

 

Technical parameters of the Syringe pump MSLIS02 :

Product name

MSLIS02 Double Channel hospital syringe pump

Flow rate

50ml syringe:0.1~1500ml/h;

30ml syringe:0.1~900.0ml/h;

20ml syringe:0.1~600.0ml/h;

10ml syringe:0.1~300.0ml/h

The range of limiting volume

0~999.9ml

The range of injected volume

0~9999.9ml

Accuracy of flow rate

Within ±3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself.)

Purge rate

Purge rate of 50ml syringe:1500ml/h;

Purge rate of 30ml syringe:900.0ml/h;

Purge rate of 20ml syringe:600.0ml/h;

Purge rate of 10ml syringe:300.0ml/h

Alarm and warms

The pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on.

Injection blocked

Choose in the three kinds of occlusion alarm pressure according to the clinical requirements(High, Medium, Low)

KVO rate

1ml/h

Fuse specification

F1AL/250V ,two fuses(installed inside pump)

Operating power

AC100~240.0V, 50/60Hz, Power:≤30VA

Internal rechargeable battery: DC 11.1V,capacity≥1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours.

Operating environment

temperature:+5~+40°C, relative humidity:20~90%

Storing environment

temperature:-30°C~+55, relative humidity:≤95%, ( No condensation state )

Atmospheric pressure

860hPa~1060hPa

Safety level

Class II with insulated enclosure, internal power supply, BF-type continuous normal running equipment.

IP grade

IPX1

Dimensions

280(L)×210(W)×255(H)(mm)

Weight

3.6kg

Accessories

Power line, operating manual, warranty card, product certification.

 

More Medical Syringe pump for you to choose!

Double Channel Medical Syringe pump MSLIS02

Double Channel Medical Syringe pump MSLIS02Double Channel Medical Syringe pump MSLIS02

 

 

 

Product consultation

Double Channel Medical Syringe pump MSLIS02 

 

 


Contact Supplier

Mr. Phil Wu Manager Chat Now
Telephone
0086-20-29078538
Mobile
86-13826448637
Fax
0086-20-84899760
Address
No. 71 and 73 Jiejin 2nd Rd, Shiqiao Town, Panyu District, Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Medical Consumables
Categories
Hi~