Dual channel syringe pump MSLIS02-M
USD $100 - $1,000 /Set
Min.Order:1 Set
Guangzhou Medsinglong Medical Equipment Co., Ltd.
MSLIS02W High Atmospheric Pressure Medical Infusion Syringe Pump with Double Channel Infusion
MSLIS01W Elastomeric Infusion Syringe Pump/Portable Clinical Injector Pump
MSLIS09W Portable into IV syringe infusion pump & Automatic Infusion Pump (door system)
MSLIS10W Brand new accurate Portable Thalassemia Syringe Pump with CE approve
Dual channel syringe pump MSLIS02-M
Product name | MSLIS02-M Dual Channel syringe pump used in hospital & clinic |
Flow rate | 50ml syringe:0.1~1500ml/h; 30ml syringe:0.1~900.0ml/h; 20ml syringe:0.1~600.0ml/h; 10ml syringe:0.1~300.0ml/h |
The range of limiting volume | 0~999.9ml |
The range of injected volume | 0~9999.9ml |
Accuracy of flow rate | Within ±3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself.) |
Purge rate | Purge rate of 50ml syringe:1500ml/h; Purge rate of 30ml syringe:900.0ml/h; Purge rate of 20ml syringe:600.0ml/h; Purge rate of 10ml syringe:300.0ml/h |
Alarm and warms | The pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on.(Safety syringe pump) |
Injection blocked | Choose in the three kinds of occlusion alarm pressure according to the clinical requirements(High, Medium, Low) |
KVO rate | 1ml/h |
Fuse specification | F1AL/250V ,two fuses(installed inside pump) |
Operating power | AC100~240.0V, 50/60Hz, Power:≤30VA Internal rechargeable battery: DC 11.1V,capacity≥1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours. |
Operating environment | temperature:+5~+40°C, relative humidity:20~90% |
Storing environment | temperature:-30°C~+55, relative humidity:≤95%, ( No condensation state ) |
Atmospheric pressure | 860hPa~1060hPa |
Safety level | Class II with insulated enclosure, internal power supply, BF-type continuous normal running equipment. |
IP grade | IPX1 |
Dimensions | 280(L)×210(W)×255(H)(mm) |
Weight | 3.6kg (Good quality syringe pump ) |
Accessories | Power line, operating manual, warranty card, product certification. |
Except for the Dual channel syringe pump, we also have one channel syringe pump, three channel and four channel syringe pump for your choose. Please see the following.
Three channel syringe pump
Four channel syringe pump