Isoflurane Anesthesia Machine - MSLGA01
USD $3,500 - $4,500 /Set
Min.Order:1 Set
Guangzhou Medsinglong Medical Equipment Co., Ltd.
Specifications
Anesthesia Machine - MSLGA01
Design
Appearance
Function
The high-precision Vaporizer (Vaporizer Definition and Vaporizer Construction) is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration.Reliable pneumatic transmission system.
Customer demand
Economic and proper configuration of technologies, optional as required by the Customer.
Modularized design and upgrading. Upgrading is available as required by the Customer.
Isoflurane Anesthesia Machine - MSLGA01
Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant | ||
Scope of application | adult, child | ||
Gas source | O2: 0.27~0.55MPa N2O: 0.27~0.55MPa | ||
Flow meter | O2: 0.1~1.0L/min 1.1~10L/min | ||
N20: 0.1~1.0L/min 1.1~10L/min | |||
O2, N2O linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off. |
Security Alarm System | |||
Oxygen Concentration alarm | upper limit setting range 21%~100% | ||
low limit setting range 10%~80% | |||
Airway pressure alarm | upper limit setting range 0.3~6.0 kPa | ||
low limit setting range 0.2~5.0 kPa | |||
Per-minute ventilation volume alarm | upper limit setting range 3.0~30L/min | ||
low limit setting range 1.0~10L/min | |||
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa | ||
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input for 15 seconds | ||
Power alarm | |||
Power | AC 220V±10% 50Hz±1Hz(UPS, Storage battery) | ||
(Mechanical Arms) (End-expiratory CO2 monitoring) | |||
Items within brackets are optional. |
Ventilation parameters | Tidal volume | 50~1500 ml (20~1500 ml) | |
Rate | 1~99 bpm | ||
SIMV rate | 2~20 bpm | ||
I:E | 2:1~1:8 (4:1~1:8) | ||
Inspiratory trigger pressure | -1.0~2.0Kpa | ||
PEEP Pressure Range | 0~2.0Kpa 1.0~6.0Kpa | ||
SIGH | 1.5 times the inspiratory time (70-150 adjustable) | ||
Inspiratory platform | 0~50% |
Respiratory circuit | working mode: all-close, semi-close, semi-open releasing pressure: 0.5~7 kPa | ||
Respiratory Bellows | bellows for adults, bellows for children tidal volume range:0~1,500 ml | ||
Ventilator (Ventilator Definition and Ventilator Function) | |||
Display mode | High-definition TFT color LCD screen display | ||
Ventilation mode | IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH, (IMV, VCV, PCV) |