MSLGA03K is an economic type of Anesthesia Machine.
1. The high-precision Vaporizer (Vaporizer Definition and Vaporizer Construction) is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
2. Reliable pneumatic transmission system.
3. Economic and proper configuration of technologies, optional as required by the Customer.
4. Modularized design and upgrading. Upgrading is available as required by the Customer.
High-grade type, High-precision evaporator, either Halothane, Enflurane, Isoflurane or Sevoflurane configuration. Double-tubes O2 flowmeter, standard loop system, ABS Engineered plastic frame, children or adult bellows, screen display ventilator (IPPV, MANUAL, ventilation volume, tidal volume, respiratory rate), real-time display of respiratory duct pressure, clear at one glance).
Enflurane anesthesia or other gas anesthesia machine
Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant |
Scope of application | adult, child |
Gas source | O2: 0.27~0.55MPa |
Flow meter | O2: 0.1~2L/min 2.5~10L/min |
Flow rate of rapid oxygen supply | 25~75L/min |
Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure < 0.2MPa |
Vaporizer | It has the function of automatic compensation based on pressure,temperature,and flow rate.The regulation range of evaporator concentration is 0~5 vol%.Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer. |
Respiratory circuit | working mode: all-close, semi-close, semi-open releasing pressure: 0.5~7 kPa |
Respiratory bellows | bellows for adults, bellows for children tidal volume range:0~1500 ml |
Ventilator | |
Display mode | digital screen display |
Ventilation mode | IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate) |
Ventilation parameters | Tidal volume 50~1500ml Rate 2~99 bpm SIMV rate 2~20 bpm I:E 2:1~1:8 Inspiratory trigger pressure -1.0~2.0 kPa Pressure range 1.0~6.0 kPa |
Parameters for ventilation monitoring | tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform |
Security Alarm System | |
Airway pressure alarm | upper limit setting range 1.0~6.0 kPa low limit setting range 0.4~2.0 kPa |
Per-minute ventilation volume alarm | upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min |
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa |
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input in 15s |
Power alarm Power | AC 220V±10% 50Hz±1Hz |