Feature
.Frequency responds up to 10kHz(970-05), 20kHZ(970-06)
.Available to be connected to oscilloscopes or "mV" range digital multimeter
.Low power consumption: 10mW approx
PTL970-05 | PTL970-06 | |
Jaw Size | Φ23mm (max) | Φ6.5mm (max) |
DCA/ACA Ranger | 4A/40A/200A | 400mA/4A/40A |
Accuracy | 2.0%rdg±0.002A(4A) 2.0%rdg±0.02A(40A) 2.0%rdg±0.02A(150A) | 2.0%rdg±0.4mA(400mA) 1.5%rdg±0.002A(4A) 1.0%rdg±0.02A(40A) |
Output Sensitivity | 0.1mV/1mA(4A) 0.1mV/10A(40A) 0.1mV/0.1A(150A) | 0.1mV/0.1mA(400mA) 0.1mV/1mA(4A) 0.1mV/10mA(40A) |
Resolution | 1mA | 0.1mA |
Power Source | 2 x AA size batteries | |
Weight | 200g |