AL/CU Conductor Rubber Insulated PVC Jacket Control Cable
USD $0.08 - $100 /Kilometer
Min.Order:1 Kilometer
Zhengzhou Hongda Cable Co., Ltd.
AL/CU Conductor Rubber Insulated PVC Jacket Control Cable
TypeDescription and Appliaction of cable
Type | Description | Main Application |
KVVZR-KVVGZR-KZZ NH-KVVKVVR-ZR-KVVR | Fire-resistant,flame-retardant or ordinary PVC insulated and PVC sheathed control cable. | For laying indoors,in trenches,in ducts and in ground. |
KVV22ZR-KVV22 GZR-KVV22NH-KVV22 | Fire-resistant,flame-retardant or ordinary PVC insulated and PVC sheathed,steel tape armored control cable. | For laying indoors,in trenches,in ducts and in ground,able to bear external mechanical forces. |
KVVPKVVP2ZR-KVVP ZR-KVVP2KVVRPZR-KVVRP | Flame-retardant or ordinary PVC insulated,PVCsheathed,control cable. | For laying indoors,in trenches,in ducts and in ground,with antiinter ference ability. |
KYJVZR-KYJV GZR-KYJVNH-KYJV | Fire-resistant,flame-retardant or ordinary XLPE insulated,PVC sheathed control cable. | For laying indoors,in trenches,in ducts and in ground. |
KYJV22ZR-KYJV22 GZR-KYJV22NH-KYJV22 | Fire-resistant,flame-retardant or ordinary XLPE insulated,PVC sheathed and steel tape armored control cable. | For laying indoors,in trenches,in ducts and in ground,able to bear external mechanical forces. |
KVVP2-22 KVVP22 | Copper-cpre PVC insulated,PVC sheathed copper tape and steel tape armored double-shield control cable. | Be applicable for weak electricity control system and strong electromagnetic field jamming area. |
Note:ZR-flame retardant G-Oxygen barrier NH-fire resistant
The rated voltages 450/750V PVC and 0.6/1kv XLPE control are used for the controlling,return circuit and protecting facilities for the rated voltages 450/750V and 0.6/1kV separtely.The working temperature of PVC and XLPE control cables are 70 and 90 separately.
Our factory developes 0.6/1kV XPLE insulated control cable based on PVC insulated and sheathed control cable for rated voltage 450/750V PVC.The flame retardant and fird resistant PVC/XLPE insulated control cable.
450/750V PVC insulated control cables are in accordance with the GB9330-88.0.6/1kV XLPE insulated control cable meets IEC60502.1.The electrical properties of flame retardant
is accordance with GB9330 Plastic insulated control cable.The property of flame retardant meets the requirements of class A,B or C of GB/T12666.5-90 Test on bunched wires or cable correspondingly.The property of fire resistant meets the class A or B requirements of the GB/T12666.6-90 Test on fire resisting characteristics of wire or cable.