Hot Selling XLPE Insulation PVC Sheathed Control Cable
USD $0.1 - $25 /Kilometer
Min.Order:1 Kilometer
Zhengzhou Hongda Cable Co., Ltd.
HOT Selling XLPE Insulated and PVC Sheathed Control Cable
plastic insulated control cable
control cable used in the site of control circuit, monitoring circuit and protective lines
1. The Control Cable products can be produced according to the standard GB9330-1988, and Control Cables are suitable for the connection of controlling electrical equipments and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
2. Type of Control Cable:
KVV Control Cable, KVVP, KVVP2, KVV22, KVVR, KVVRP, KYJV, KYJVP, KYJV22 Control Cable, KYJV22, KYJVP2, KYJVR, KYJVRP Control Cable
Type | Name | Section Area(mm2) | No. of Core | Application Site |
KVV | Copper Conductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KVVRP | Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
1.5 2.5 | 4-48 | |||
KYJV | Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KYJVRP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable | 0.5 0.75 1.0 | 4-61 |
|
|
| 1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |
Control cables are used in the site of control circuit, monitoring circuit and protective lines that have A.C rated voltage of 600/1000 V and below.
Standards
They comply well with IEC 60227, IEC60502, IEC 60332-3, IEC 60754-1 and IEC 61034 etc.
Features
The maximum allowable temperature of conductor is 90 0C for XLPE cable or 700C for PVC cable at normal operation.
The temperature not less than 0 0C when cables laid.
Installation bending radius of cable: 6D for no-armor or with screen layer flexible cable.
12D for armor or copper tape screen cables.
(D=overall diameter of cable)