1220mm/915mm Marley MX75 Cooling Tower Fill, Marley MX75 PVC Fill
USD $0.35 - $0.58 /Piece
Min.Order:500 Pieces
Hebei Sinta FRP Trading Co., Ltd.
Raw material cooling tower fill replacement, Crossflow 305*1830 cooling tower filler packing
Raw material cooling tower fill replacement, Crossflow 950*950 cooling tower filler packing
sinta supply Cross flow cooling tower infill/PVC filler for cooling tower
Liangchi 750*800 cooling tower fill, PVC fill for Cooling Tower
5 feet width Marley MX75 cooling tower fill with high performance is one of the most important components for exchange of gas and water in cooling tower. It is the major parts to improve the efficiency of cooling tower and make sure the economy and safe operation. With the development of the plastic industry, counter current tower drench water plastic packing "S" shape ladder wave, obliquely wave, which has the heat dissipation, good performance, ventilated small resistance, durable, based on the easy and other advantages, it is widely used in different types of large, medium, small cooling tower.
Marley cooling tower fill fetures:
1. Improved water distribution
2. High thermal performance
3. Material meets Cooling Tower Institute
4.Mainly apply to Counterflow fill.
MX75 cooling tower fill Technical Data:
MX Fill is available in MX75 configuration and higher-performing MX625 configuration. MX is a hanging film type cooling tower fill which spreads the water into a thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow. This type of fill provides much more water surface exposure per cubic foot than splash type fill.
MX fill incorporates highly efficient cellular drift eliminators, integrally molded within the fill sheets. Compared with previous designs, these eliminators reduce drift emissions from the tower by a factor of ten or more! Less drift means tower owners save water bills and water treatment chemical expenses.
This fill virtually eliminates the nuisance caused by drift spotting on adjacent buildings and property. For additional savings, the drift eliminators discharge air directly toward the fan. Discharge air, traveling in the right direction when it leaves the eliminators, translates to lower fan horsepower.
Louvers are also integrally molded within the fill sheets preventing water from escaping and assuring precise air distribution throughout wide variations in airflow. Unlike towers equipped with separate external louvers, this fill operates virtually ice-free even in extremely cold weather.
MX fill is thermoformed from PVC with a flame spread rating less than 25 per ASTM E-84 and is considered selfextinguishing. Therefore, the risk of fire damage is minimal.
Characteristics | Units | 12 mm | 19 mm | 27 mm |
Cooling Towers Application | Counterflow | Counterflow | Counterflow | |
Flute height | mm | 12 | 19 | 27 |
Longitudinal pitch | mm | 38 | 50 | 70 |
Spiral angle | °(degree) | 28 | 28 | 28 |
Surface area per unit volume | m²/m³ | 243 | 157 | 120 |
Maximum continuous Operating temp. | °C °F | 55 131 | 55 131 | 55 131 |
Standard Fill Sheet Finished Thickness | mm | 0.3 | .3 | 0.3 |
We have many years for exported Cooling towers filling, we are professional for installation and production .
MX75 PVC Fill for Marley Cooling Tower Weight:
NOMINAL GAUGE | DRY WEIGHT | ||
mils | mm | lbs/ft3 | kg/m3 |
10 | 0.25 | 1.8 | 28.8 |
15 | 0.38 | 2.6 | 41.6 |
Above Data is for PVC material .
MX75 Marley cooling tower media pictures:
MX75 cooling tower fill packages:
MX75 PVC fill application:
Other cooling tower fill/PVC fill for cooling tower pictures:
If you are interested in our products, please don't hesitate to contact with us.