33kv xlpe power cable Copper or CCA core cables and wires
Negotiable /Meter
Min.Order:5000 Meters
Yueqing Rixing Cable Technology Co., Ltd.
33kv xlpe power cable Copper or CCA core cables and wires Copper or CCA core cables and wires Copper or CCA core cables and wires Copper or CCA core cables and wires
1 Standard
GB 5023.11997 , JB 8734.15-1998, Q/ZEL 02-2002, GB 5023.17-1997, IEC227
2 Voltages U0/U:
450/750V300/500V300/300V.(600/1000V also available)
Max. permissible continuous operating temperature of the conductor: 70
The ambient temperature under installation should not below 0.
Impedance (ohms): 100±2ohm
3 Application
The products is suitable for use in power installations, fixed wiring or flexible
connections for electrical appliances like lighting, electronic equipment, instrument
and communication equipment with rated voltage 450/750V or less
4 Model and Name
Model | Name |
BV | Copper Core PVC Insulation Wire |
BLV | Aluminum Core PVC Insulation Wire |
BVR | Copper Core PVC Insulation Flexible Wire |
BVV | Copper Core PVC Insulation PVC Sheath Round Wire |
BVVB | Copper Core PVC Insulation PVC Sheath Flat Wire |
BLVVB | Aluminum Core PVC Insulation PVC Sheath Flat Wire |
BV-90 | Copper Core Heat-resistance 105oC PVC Insulation |
5 Specification Size and Technical Data
Commen wire
Nominal sectional area mm2 | Conductor No/Dia. mm | Nominal Insulated thick mm | Max overall Dia. mm | Condcutor Resistance at 20 | Min insulated resistance at 70MΩ/km | Weight Kg/km | ||
Cu | Al | Cu | Al | |||||
1.5 | 1/1.38 | 0.7 | 3.3 | 12.1 | - | 0.011 | 19.2 | - |
1.5 | 7/0.52 | 0.7 | 3.5 | 12.1 | - | 0.010 | 20.6 | - |
2.5 | 1/1.78 | 0.8 | 3.9 | 7.41 | 11.8 | 0.010 | 30.8 | 15.0 |
4 | 1/2.25 | 0.8 | 4.4 | 4.61 | 7.39 | 0.0085 | 45.5 | 21.0 |
6 | 1/2.76 | 0.8 | 4.9 | 3.08 | 4.91 | 0.0070 | 65.0 | 29.0 |
10 | 7/1.35 | 1.0 | 7.0 | 1.83 | 3.08 | 0.0065 | 110.0 | 52.0 |
16 | 7/1.70 | 1.0 | 8.0 | 1.15 | 1.91 | 0.0050 | 170.0 | 70.0 |
25 | 7/2.14 | 1.2 | 10.0 | 0.727 | 1.20 | 0.0050 | 270.0 | 110.0 |
35 | 7/2.52 | 1.2 | 11.5 | 0.524 | 0.868 | 0.0040 | 364.0 | 150.0 |
50 | 19/1.78 | 1.4 | 13.0 | 0.387 | 0.641 | 0.0045 | 500.0 | 200.0 |
70 | 19/2.14 | 1.4 | 15.0 | 0.268 | 0.443 | 0.0035 | 688.0 | 269.0 |
95 | 19/2.52 | 1.6 | 17.5 | 0.193 | 0.320 | 0.0035 | 953.0 | 360.0 |
120 | 37/2.03 | 1.6 | 19.0 | 0.153 | 0.253 | 0.0032 | 1168.0 | 449.0 |
150 | 37/2.25 | 1.8 | 21.0 | 0.124 | 0.206 | 0.0032 | 1466.0 | 551.0 |
185 | 37/2.52 | 2.0 | 32.5 | 0.099 | 0.164 | 0.0032 | 1808.0 | 668.0 |
Flexible wire
Nominal sectional area mm2 | Conductor No/Dia. mm | Nominal Insulated thick mm | Max overall Dia. mm | Condcutor Resistance at 20 | Min insulated resistance at 70MΩ/km | Weight Kg/km |
2.5 | 9/0.41 | 0.8 | 4.2 | 7.41 | 0.011 | 33.0 |
4 | 19/0.52 | 0.8 | 4.8 | 4.61 | 0.009 | 48.0 |
6 | 19/0.64 | 0.8 | 5.6 | 3.08 | 0.0084 | 68.0 |
10 | 49/0.52 | 1.0 | 7.6 | 1.83 | 0.0072 | 115.0 |
16 | 49/0.64 | 1.0 | 8.8 | 1.15 | 0.0062 | 176.0 |
25 | 98/0.58 | 1.2 | 11.0 | 0.727 | 0.0058 | 272.0 |
35 | 133/0.58 | 1.2 | 12.5 | 0.524 | 0.0052 | 384.0 |
50 | 133/0.68 | 1.4 | 16.5 | 0.387 | 0.0051 | 510.0 |
70 | 189/0.68 | 1.4 | 16.5 | 0.268 | 0.0045 | 714.0 |
95 | 259/0.68 | 1. | 19.5 | 0.139 | 0.0035 | 965.0 |
120 | 259/0.76 | 1.8 | 22.0 | 0.153 | 0.0032 | 1210.0 |
150 | 259/0.85 | 1.8 | 25.0 | 0.124 | 0.0032 | 1510.0 |