AA320N Atomic Absorption Spectrophotometer price cheap
USD $8,186 - $8,200 /Set
Min.Order:1 Set
Shanghai Yanhe Instrument Equipment Co., Ltd.
AA320N Atomic Absorption Spectrophotometer
COMMON FEATURES
1.Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak
height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting,
various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for
externally linking PC.
2.Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by
the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line
stability) and electronic circuit drift so as to reach a good basic line stability.
3.Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the
preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
4.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to
ensure a high precision analytical test and low characteristic concentration
5.High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of
chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.
6.Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and
fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
7.Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption
and hydride generation.
8.Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to
analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more
than 60.
9.Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.
STANDARD ACCESSORIES
Oil-free air compressor
Glass Atomizer
Cu Hollow cathode lamp
Atomizer unit
Burner unit
Dust cover
Water-separating gas filter
Titanium burner---10cm
OPTIONAL ACCESSORIES
Model GA3202 HGA graphite furnace system
Hydride generator
Graphite tubes
Acetylene Regulator YQE-213
Software
Recirculating cooling water system