CE RoHS ISO9001 AD-155B 155W 13.8V 13.3V Automatic Battery Charger
USD $24.68 - $25.69 /Piece
Min.Order:1 Piece
Yueqing Leyu Electric Automation Co., Ltd.
CE RoHS 155W 54.0V 53.5V AD-155C DC current power supply with UPS function
SCP-60A Single output power supply 13.8V LED power supply with battery charger
SCP-60B 27.6Volt switch mode power supply 2.15 0.75 Amp for led strip lights with CE RoHS
55W Security SMPS with Battery Charger UPS Function AD-55A power supply 13.8v
12v 24v automatic battery charger
CE RoHS ISO9001 155W 12V 24V Automatic Battery Charger
FAQ -power inverter
1. Do you accept OEM for the power inverter ?
Yes. we do .
2 .What certificated do you have ?
CE RoHS ISO9001
3.How to Contact Us ?
Send your inquiry Details in the below, Click "Send" Now !
Not exactly what you want? Post a quick Buying Request!
Welcome to your inquiry, Hilary waiting for you !
155W Single Output with Battery Charger (UPS Function) AD-155 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low and battery polarity protection
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
2 year warranty
SPECIFICATION | ||||||
MODEL | AD-155A | AD-155B | AD-155C | |||
OUTPUT |
|
|
| |||
Output number | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC voltage | 13.8V | 13.3V | 27.6V | 27.1V | 41.4V | 41V |
Rated Current | 10.5A | 0.5A | 5A | 0.5A | 3.6A | 0.2A |
Current Range | 0~11.5A | 0-0.5A | 0~5.5A | 0-0.5A | 0-2.7A | 0-0.5A |
Rated Power | 151.55W | 151.55W | 156.5W | |||
Ripple & Noise | 100mVp-p | -------- | 150mVp-p | -------- | 240mVp-p | -------- |
Voltage Adj. Range | CH1:12~14.5V | CH1:24~29V | CH1:36V-43V | |||
Voltage Tolerance | ±2.0% | -------- | ±1.0% | -------- | ±1.0% | -------- |
Line Regulation | ±0.5% | -------- | ±0.5% | -------- | ±0.5% | -------- |
Load Regulation | ±0.5% | -------- | ±0.5% | -------- | ±0.5% | -------- |
Setup, Rise Time | 1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load | |||||
Hold Up Time | 24ms/230VAC 20ms/115VAC at full load | |||||
|
| |||||
INPUT |
| |||||
Voltage Range | 88~264VAC 47~63Hz; 124~370VDC | |||||
AC Current | 2.5A/115VAC 1.5A/230VAC | |||||
Efficiency | 80% | 84% | 84% | |||
Inrush Current | Cold start 20A/115VAC 40A/230VAC | |||||
Leakage Current | <1mA /240VAC | |||||
|
| |||||
PROTECTION |
| |||||
Over Load | CH1:105 ~ 135% CH2:0.51 ~ 0.9A rated output power | |||||
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse | ||||||
Over Voltage | CH1:15.87~18.63V | CH1:31.74~37.26V | CH1:62.1 ~ 72.9V | |||
Protection type:Shut down o/p voltage, re-power on to recover | ||||||
Battery Low | 10V±0.8V | 19.5V(+1.5V,-1V ) | 39V±2V | |||
|
| |||||
ENVIRONMENT |
| |||||
Working Temp. | -10~+60℃ (Refer to “Derating Curve”) | |||||
Working Humidity | 20~90%RH non-condensing | |||||
Storage Temp., Humidity | -20~+85℃,10~95%RH | |||||
Temp. Coefficient | ±0.03%/ ℃(0~50℃ ) | |||||
Vibration | 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes | |||||
|
| |||||
SAFETY &EMC |
| |||||
Safety Standards | UL60950-1, TUV EN60950-1 | |||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
| |||||
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH
| |||||
EMC Emission | Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 | |||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A | |||||
|
| |||||
OTHERS |
| |||||
Dimension | 199*110*50mm (L*W*H) | |||||
Weight | 0.72Kg | |||||
Packing | 20pcs/carton | |||||
NOTE |
| |||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |