Features:·AC input voltage range selected by switc
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·Indicator for power on/charge/normal(LED)
·100% full load burn-in test
·Battery protection at low voltage
·2 Yeas warranty
Model | SCP-75-12 | SCP-75-24 | ||||
output | DC voltage | CH1:13.8V | CH1:13.4V | CH1:27.6V | CH2:26.5V | |
Voltage tolerance | ±1% | ----- | ±1% | ----- | ||
Rated current | 5A | 0.5A | 2.5A | 0.3A | ||
Current range | 0~5A | ----- | 0~2.5A | ----- | ||
Rated power | 75.7W | 76.9W | ||||
Ripple&noise | 120mvp-p | ----- | 180mvp-p | ----- | ||
DCvoltage ADJ.range | CH1:11.3~14.9V | CH1:21.3~29.8V | ||||
input | Voltage range | 90~264VAC,127~370VDC | ||||
frequency | 47~63HZ | |||||
AC current | 2.8A/115VAC,1.4A/230VAC | |||||
efficiency | 81% | 83% | ||||
Inrush current | Cold start current 30A/115VAC,50A/230VAC | |||||
Leakage current | < 1mA/240VAC | |||||
protection | Over load | Rated output power110%~150% start over load protection | ||||
protection mode: AC charging mode:hiccup mode auto-recovery after fault condition is removed | ||||||
Battery protection At low voltage | 9.5~11V | 20~22V | ||||
protection mode:cutoff output | ||||||
Function | UPS introduction | long-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop harging when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch,no switch time,no need human guard, cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs | ||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | ||||
Storagetemp,humidity | -20℃~+85℃,10%~95%RH non-condensing | |||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | |||||
safety | Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | |||||
Fitstandard | Safety standard | Compliance to UL60950-1 | ||||
EMC standard | Compliance to EN55022,CLASSB | |||||
others | Dimension | 159*97*38mm (L*W*H) | ||||
Weight/packing | 0.53kg/piece 40pcs/carton | |||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
1. Do you accept OEM for the switching power supply ?
Yes. we do .
2 .What certification you have for the switching power supply ?
We have CE , ROHS , CCC , ISO9001 , IP67
3.How to Contact Us ?
Send your inquiry Details in the below, Click "Send" Now !
Not exactly what you want? Post a quick Buying Request!
Whatsapp: +8618046718945