Factory Manufacture 120w triple output power supply CE RoHS approved T-120 switch mode power supply
USD $15.77 - $17.56 /Piece
Min.Order:1 Piece
Yueqing Leyu Electric Automation Co., Ltd.
CE Approval T-30A 5V 12V -5v triple output switching power supply 30w
Factory Manufacture T-30A 5V 12V -5V output 30W triple output switch power supply
Factory Manufacture T-30B 5V 12V -12V output 30W triple output transformer
Factory Manufacture T-30B triple output 5V 12V -12V power supply with CE RoHS
2 years warranty triple output 5v 12v -5v 35w switching power supply
Factory Manufacture 120w triple output power supply CE RoHS approved T-120 switch mode power supply
Specification:
120W Triple Output Switching Power Supply T-120 series
Features:
Low price and high reliability
105℃output capacitor
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With Short-circuit and overload protection
Compact size, light weight
100% full-load burning test
Installed with EMI filter, minimum wave
SPECIFICATIONS | ||||||||||||
OUTPUT |
| |||||||||||
Model | T-120A | T-120B | T-120C | T-120D | ||||||||
Output number | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC Voltage | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
Rated Current | 11A | 5A | 1A | 11A | 4.5A | 1A | 10A | 2.5A | 1A | 2A | 7A | 1A |
Current Range | 2-11A | 0.5-5A | 0.2-1A | 2-11A | 0.5-4.5A | 0.2-1A | 2-10A | 0.5-2.5A | 0.2-1A | 1-2A | 0.5-7A | 0.2-1A |
Rated Power | 120W | 121W | 118W | 118W | ||||||||
Ripple & Noise | 80mVp-p | 120mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 80mVp-p | 150mVp-p | 150mVp-p | 80mVp-p | 120mVp-p | 180mVp-p |
Voltage Adj. Range | CH1;+10,-5% | CH1:+10,-5% | CH1:+10,-5% | CH2:+10,-5% | ||||||||
Voltage Tolerance | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% | ±2% | ±6% | ±6% |
Inlet Stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±1% |
Load Stability | ±2% | ±6% | ±6% | ±2% | ±6% | ±6% | ±2% | ±6% | ±6% | ±2% | ±6% | ±6% |
Setup, Rise, Hold Up Time | 200ms,50ms,20ms at full load | |||||||||||
|
| |||||||||||
INPUT |
| |||||||||||
Voltage Range | 85~132VAC/176~264VAC selected by switch 47~63Hz; 240~370VDC | |||||||||||
AC Current | 2.5A/115V 1.25A/230A | |||||||||||
Efficiency | 77% | 77% | 76% | 80% | ||||||||
Inrush Current | Cold start 30A/115V 60A/230V | |||||||||||
Leakage Current | <3.5mA/240VAC | |||||||||||
|
| |||||||||||
PROTECTION |
| |||||||||||
Over Load | 105%~150% | |||||||||||
Protection type: Fold back: current limiting; reset: auto recovery | ||||||||||||
|
| |||||||||||
ENVIRONMENT |
| |||||||||||
Working Temp., Humidity | -10℃~+60℃(Refer to output derating curve), 20%~90%RH | |||||||||||
Storage Temp., Humidity | -20℃~+85℃,10%~95%RH | |||||||||||
Temp. Coefficient | ±0.03%/℃(0-50℃) ON+5V | |||||||||||
Vibration | 10-500Hz,2G 10min,/1cycle,Period for60min,Each axes | |||||||||||
|
| |||||||||||
SAFETY |
| |||||||||||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||||||||
|
| |||||||||||
STANDARD |
| |||||||||||
Safety Standard | Meet UL 1012 requirement(Not apply for the mark) | |||||||||||
EMC Standard | ………… | |||||||||||
|
| |||||||||||
OTHERS |
| |||||||||||
Dimension | 199*110*50mm(L*W*H) | |||||||||||
Weight | 0.9Kg | |||||||||||
|
| |||||||||||
NOTE |
| |||||||||||
1.The testing condition for the paramenter above is :230VAC input,rated load,25℃70% RH.Humidity. 2.Error.include the setting error,line stability and load stability.(Note:5). 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. 6.Total output canbe maximum Current,total load can not exceed the maximum output power |
Detailed Photos :
What is our magic weapon for winning?
1.10 years experience for producing Electric Appliances
2. Independent research and development ability, with 15 years experience of engineers.
3. No one we have, we have excellent!
How to Contact Us ?
Send your inquiry Details in the below, Click "Send" Now !
Not exactly what you want? Post a quick Buying Request!
Grace is waiting for your kind inquiry !