SMPS NES-150-12V best quality 150W 12V fonte de energia(power supply) with CE RoHS
USD $10.05 - $14.32 /Piece
Min.Order:1 Piece
Yueqing Leyu Electric Automation Co., Ltd.
fonte de energia (power supply)
Specification:
150W Single Output Switching Power Supply NES-150 series
Features:
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High efficiency, long life and high reliability
2 years warranty
SPECIFICATION |
| |||||||||||||
OUTPUT |
| |||||||||||||
Model | NES-150-5 | NES-150-12 | NES-150-15 | NES-150-24 | NES-150-48 | NES-150-50 | ||||||||
DC Voltage | 5V | 12V | 15V | 24V | 48V | 50v | ||||||||
Rated Current | 26A | 12.5A | 10A | 6.5A | 3.3A | 3A | ||||||||
Current Range | 0~26A | 0~12.5A | 0~10A | 0~6.5A | 0~3.3A | 0-3A | ||||||||
Rated Power | 130W | 150W | 150W | 156W | 158.4W | 150W | ||||||||
Ripple & Noise | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | 200mVp-p | ||||||||
Voltage Adj. Range | 4.75 ~5.5V | 11.4 ~ 13.5V | 14.25 ~ 16.5V | 22.8 ~ 27.6V | 45.6 ~ 52.8V | 45~55V | ||||||||
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||||
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||||
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||||
Setup, Rise Time | 800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | |||||||||||||
Hold Up Time | 24ms/230VAC 20ms/115VAC at full load | |||||||||||||
|
| |||||||||||||
INPUT |
| |||||||||||||
Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 373VDC | |||||||||||||
Frequency Range | 47 ~ 63Hz | |||||||||||||
Efficiency | 78% | 83% | 83% | 86% | 86% | 86% | ||||||||
AC Current | 3A/115VAC 2A/230VAC | |||||||||||||
Inrush Current | Cold Start 45A/230VAC | |||||||||||||
Leakage Current | <2mA / 240VAC | |||||||||||||
|
| |||||||||||||
PROTECTION |
| |||||||||||||
Over Load | 110 ~ 150% rated output power | |||||||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||||
Over Voltage | 3.8 ~ 4.65V | 5.75 ~ 6.75V | 8.6 ~ 10.1V | 10.4 ~ 12.2V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | 63.2~74.2V | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||||
|
| |||||||||||||
ENVIRONMENT |
| |||||||||||||
Working Temp. | -20 ~ +60℃ (Refer to output load derating curve) | |||||||||||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||||||||||
Storage Temp., Humidity | -40 ~ +85℃, 10 ~ 95% RH | |||||||||||||
Temp. Coefficient | ±0.03%/℃ (0 ~ 50℃) | |||||||||||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||||||||
|
| |||||||||||||
SAFETY & EMC |
| |||||||||||||
Safety Standards | UL60950-1, CB(IEC60950-1),CCC GB4943 approved | |||||||||||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH | |||||||||||||
EMI Conduction & Radiation | Compliance to EN55022 (CISPR22) Class B,GB9254 CLASS B | |||||||||||||
Harmonic Current | Compliance to EN61000-3-2,-3,GB17625.1 | |||||||||||||
EMC Immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, heavy industry level, criteria A | |||||||||||||
|
| |||||||||||||
OTHERS |
| |||||||||||||
Dimension | 199*98*38mm (L*W*H) | |||||||||||||
Weight | 0.7Kg | |||||||||||||
Packing | 30pcs/carton | |||||||||||||
|
| |||||||||||||
NOTE |
| |||||||||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |
Detail photos:
Certification:
What is our magic weapon for winning?
1.10 years experience for producing Electric Appliances.
2. Independent research and development ability, with 15 years experience of engineers.
3. No one we have, we have excellent!
Grace is waiting for your kind inquiry !