Factory Supply Dual Output 155W UPS Function CE Approved Battery Switch power
USD $28.95 - $32 /Piece
Min.Order:1 Piece
Yueqing Leyu Electric Automation Co., Ltd.
Battery charger CE RoHS ADD-155B 27.6V small volume dual output 155W 27.6v power supply
Battery charger with UPS function ADD-155B Dual output 155w power supply
LEYU ADD-155C dual output 155w with battery charger 54V power supply
Newest ADD-155C 155w with battery charger 13.8V 27.6V 54.0V dual output power supply
battery switch power
Specification:
155W Dual Output with Battery Charger (UPS Function) ADD-155 series
Features:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low protections
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45 KHz
1 year warranty
SPECIFICATION | ||||||||||||||
MODEL | ADD-155A | ADD-155B | ADD-155C | |||||||||||
OUTPUT |
|
|
| |||||||||||
Output number | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |||||
DC voltage | 13.8V | 5V | 13.3V | 27.6V | 5V | 27.1V | 54 V | 5 V | 53.5 V | |||||
Rated Current | 9.5A | 3A | 0.5A | 3A | 3A | 0.5A | 0.2A | 4.5A | 2.3A | |||||
Current Range | 0~10.5A | 0~3A | -------- | 0~5A | 0~3A | --------- | 0~2.5A | 0~3A | --------- | |||||
Rated Power | 152.75W | 152.75W | 149.9W | |||||||||||
Ripple & Noise | 150mVp-p | 100mVp-p | -------- | 200mVp-p | 100mVp-p | ------- | 200mVp-p | 100mVp-p | -------- | |||||
Voltage Adj. Range | CH1:12~14.5V | CH1:24~29V |
| |||||||||||
Voltage Tolerance | ±2.1% | ±0.5% | -------- | ±1.0% | ±0.5% | -------- | ±1.0% | ±5.0% | -------- | |||||
Line Regulation | ±1.0% | ±2.0% | -------- | ±1.0% | ±2.0% | -------- | ±1.0% | ±0.5% | -------- | |||||
Load Regulation | ±1.0% | ±3.0% | -------- | ±1.0% | ±3.0% | -------- | ±1.0% | ±2.0% | -------- | |||||
Setup, Rise Time | 1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load | |||||||||||||
Hold Up Time | 24ms/230VAC 20ms/115VAC at full load | |||||||||||||
|
| |||||||||||||
INPUT |
| |||||||||||||
Voltage Range | 88~264VAC 47~63Hz; 124~370VDC | |||||||||||||
AC Current | 2.5A/115VAC 1.5A/230VAC | |||||||||||||
Efficiency | 78% | 81% | 81% | |||||||||||
Inrush Current | Cold start 20A/115VAC 40A/230VAC | |||||||||||||
Leakage Current | <1mA /240VAC | |||||||||||||
|
| |||||||||||||
PROTECTION |
| |||||||||||||
Over Load | CH1,CH2:105 ~ 135% CH3:0.51 ~ 0.9Arated output power | |||||||||||||
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse | ||||||||||||||
Over Voltage | CH1:15.87~18.63V | CH1:31.74~37.26V | CH1:62.1~72.9V | |||||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||||
Battery Low | 10V±0.8V | 19.5V±1.5V | 39V±2V | |||||||||||
|
| |||||||||||||
ENVIRONMENT |
| |||||||||||||
Working Temp. | -10~+60℃ (Refer to “Derating Curve”) | |||||||||||||
Working Humidity | 20~90%RH non-condensing | |||||||||||||
Storage Temp., Humidity | -20~+85℃,10~95%RH | |||||||||||||
Temp. Coefficient | ±0.03%/ ℃(0~50℃ )on CH1 output | |||||||||||||
Vibration | 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes | |||||||||||||
|
| |||||||||||||
SAFETY &EMC |
| |||||||||||||
Safety Standards | Design refer to UL60950-1, TUV EN60950-1 | |||||||||||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||||||
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH | |||||||||||||
EMC Emission | Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 | |||||||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A | |||||||||||||
|
| |||||||||||||
OTHERS |
| |||||||||||||
Dimension | 119*11*50mm(L*W*H) | |||||||||||||
Weight | 1Kg | |||||||||||||
Packing | 20pcs/12.6Kg/0.75CUFT | |||||||||||||
|
| |||||||||||||
NOTE |
| |||||||||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Detailed photos :