2 Year Warranty CE RoHS 60W dc dc converter 24v 5v
USD $13.16 - $14.15 /Piece
Min.Order:1 Piece
Yueqing Leyu Electric Automation Co., Ltd.
dc dc converter 24v 5v
2 Year Warranty CE RoHS 60W dc dc converter 24v 5v
60W Single Output DC-DC Converter SD-60 series
Features :
2:1 wide input range
Protections: Short circuit / Overload / Over voltage
1500VAC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83KHz
Low cost
High reliability
2 year warranty
SPECIFICATION | |||||||||
OUTPUT |
| ||||||||
Model | SD-60-5 | SD-60-12 | SD-60-24 | ||||||
DC Voltage | 5V | 12V | 24V | ||||||
Rated Current | 12A | 5A | 2.5A | ||||||
Current Range | 0~12A | 0~5A | 0~2.5A | ||||||
Rated Power | 60W | 60W | 60W | ||||||
Ripple & Noise | 100mVp-p | 120mVp-p | 150mVp-p | ||||||
Voltage Adj. Range | 4.5~5.5VDC | 11~16VDC | 23~30VDC | ||||||
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ||||||
Line Regulation | ±0.5% | ±0.3% | ±0.2% | ||||||
Load Regulation | ±0.5% | ±0.3% | ±0.2% | ||||||
Setup, Rise, Hold Up Time | 2.5s,50ms,------at full load | ||||||||
|
| ||||||||
INPUT |
| ||||||||
Voltage Range | 48VAC | ||||||||
Efficiency | 70% | 73% | 76% | 72% | 75% | 78% | 74% | 80% | 83% |
AC Current | 7A/12V | 3A/24V | 1.5A/48V | ||||||
|
| ||||||||
PROTECTION |
| ||||||||
Over Load | 105~150% rated output power | ||||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||||
Over Voltage | 5.75~6.75V/10%load | 16.8~20V/10%load | 31.5~37.5V/10%load | ||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||||
|
| ||||||||
ENVIRONMENT |
| ||||||||
Working Temp. | -10~+60℃ (Refer to "Derating Curve") | ||||||||
Working Humidity | 20~90% RH non-condensing | ||||||||
Storage temp., Humidity | -20~+85℃ ,10~95%RH | ||||||||
Temp. Coefficient | ±0.03%/℃ (0~50℃) | ||||||||
Vibration | 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes | ||||||||
|
| ||||||||
SAFETY & EMC |
| ||||||||
Safety Standards | Design refer to LVD | ||||||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
| ||||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC /25℃ /70%RH
| ||||||||
EMC Emission | Compliance to EN55022(CISPR22)Class B | ||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,6,8, EN55024, heavy industry level, criteria A | ||||||||
|
| ||||||||
OTHERS |
| ||||||||
Dimension | 159*97*38mm(L*W*H) | ||||||||
Weight | 0.48Kg | ||||||||
Packing | 24pcs/12.7Kg/0.75CUFT | ||||||||
|
| ||||||||
NOTE |
| ||||||||
1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |