High Efficiency 120W dc converter 12v to 5v
USD $18.05 - $19.18 /Piece
Min.Order:1 Piece
Yueqing Leyu Electric Automation Co., Ltd.
12v to 5v
High Efficiency 120W dc converter 12v to 5v
120W Single Output DC-DC Converter SD-120 series
Features :
2:1 wide input range
Protections: Short circuit / Overload / Over voltage
1500VAC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83KHz
24V and 48V input voltage design refer to LVD
Low cost
High reliability
2 year warranty
SPECIFICATION | |||||||||
OUTPUT |
| ||||||||
Model | SD-120B-5 | SD-120C-5 | SD-120D-5 | SD-120B-12 | SD-120C-12 | SD-120D-12 | SD-120B-24 | SD-120C-24 | SD-120D-24 |
DC Voltage | 5V | 12V | 24V | ||||||
Rated Current | 24A | 10A | 5A | ||||||
Current Range | 0~24A | 0~10A | 0~5A | ||||||
Rated Power | 120W | 120W | 120W | ||||||
Ripple & Noise | 100mVp-p | 120mVp-p | 150mVp-p | ||||||
Voltage Adj. Range | 4.5~5.5VDC | 11~16VDC | 23~30VDC | ||||||
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ||||||
Line Regulation | ±0.5% | ±0.3% | ±0.2% | ||||||
Load Regulation | ±0.5% | ±0.3% | ±0.2% | ||||||
Setup,Rise Time | 2s,50ms(only D mode) at full load | ||||||||
Hold Up Time | 20ms(only D mode) at full load | ||||||||
|
| ||||||||
INPUT |
| ||||||||
Voltage Range | B:19~36VDC C:36~72VDC D:72~144VDC or 85~132VAC | ||||||||
Efficiency | 74% | 75% | 76% | 75% | 77% | 80% | 78% | 81% | 83% |
DC Current | 4.8A/24V | 2.4A/48V | 1.8A/96V | 4.8A/24V | 2.4A/48V | 1.8A/96V | 4.8A/24V | 2.4A/48V | 1.8A/96V |
Inrush Current | D:18A/96VDC | ||||||||
Leakage Current | <0.75mA/120VAC(SD-100D) | ||||||||
|
| ||||||||
PROTECTION |
| ||||||||
Over Load | 105~135% rated output power | ||||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||||
Over Voltage | 5.75~6.75V/10%load | 16.8~20V/10%load | 31.5~37.5V/10%load | ||||||
Protection type:Hiccup mode,recovers automatically after fault condition is removed | |||||||||
|
| ||||||||
ENVIRONMENT |
| ||||||||
Working Temp. | -10~+60℃ (Refer to “Derating Curve”) | ||||||||
Working Humidity | 20~90%RH non-condensing | ||||||||
Storage Temp.,Humidity | -20~+85℃,10~95%RH | ||||||||
Temp.Coefficient | ±0.03%/℃ (0~50℃) | ||||||||
Vibration | 10~500Hz,2G 10min./1cycle,60min.each along X, Y, Z axes | ||||||||
|
| ||||||||
SAFETY &EMC |
| ||||||||
Safety Standards | IEC60950-1CB approved by TUV(for D type only) | ||||||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||||
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH | ||||||||
EMC Emission | Compliance to EN55022(CISPR22) Class B | ||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,6,8,light industry level,criteria A | ||||||||
|
| ||||||||
OTHERS |
| ||||||||
Dimension | 199*98*38mm(L*W*H) | ||||||||
Weight | 0.65Kg | ||||||||
Packing | 20pcs/13.8Kg/0.8CUFT | ||||||||
|
| ||||||||
NOTE |
| ||||||||
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |