19" 3U 5KVA rack-mount telecom power inverter with AC DC priority choosen by user
USD $1,800 - $2,500 /Unit
Min.Order:1 Unit
Features :
Pure sine wave output (THD < 3%) R load
Inverter mode or UPS mode
By pass function
Output frequency : 50/60Hz switch
RS-232 interface / remote controls port / Wire connection to PC
Optional : SNMP interface / DC input 110/220 / door / 5 sets dry contacts (voltage free)
Wired Remote control
Loading controlled cooling fan
Advanced microprocessor
Protection : Input Undervoltage, Input Overvoltage, Overload, Short circuit, Low battery alarm, Over temperature
AC output sockets : Universal / UK / SCHUKO / USA / Australia/New Zealand / Terminal / IEC
Specification | Model | |||||||
Item | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW |
Continuous Output Power | 5000W | |||||||
Maximum Output Power | 5200W (3 mins) | |||||||
Surge Rating | 10000W | |||||||
Input Voltage | 24V | 48V | 110V | 220V | 24V | 48V | 110V | 220V |
Input Voltage Range | 20-32 | 42-62 | 90-140 | 180-275 | 20-32 | 42-62 | 90-140 | 180-275 |
DC Input over voltage alarm | 31.0VDC | 61.0VDC | 135VDC | 270VDC | 31VDC | 61.0VDC | 135VDC | 270VDC |
DC Input over voltage shut-down | 32.0VDC | 62.0VDC | 140VDC | 275VDC | 32.0VDC | 62.0VDC | 140VDC | 275VDC |
DC Input under voltage alarm | 21.0VDC | 43.0VDC | 95VDC | 185VDC | 21.0VDC | 43.0VDC | 95VDC | 185VDC |
DC Input under voltage shut-down | 20.0VDC | 42.0VDC | 90VDC | 180VDC | 20.0VDC | 42.0VDC | 90VDC | 180VDC |
No load Current Draw | 1.64A | 0.82A | 0.42A | 0.24A | 1.3A | 0.68A | 0.35A | 0.18A |
Output Voltage Adjustment | 100 ~ 120V (Tune VR) | 200~240V (Tune VR) | ||||||
Frequency | 50/60Hz ± 0.05% ( Switch Selectable) | |||||||
Peak Output Current | 91A | 45A | ||||||
Efficiency (full load) | 85% | 87% | 90% | 92% | 90% | 92% | 94% | 94% |
Output Waveform | R Load Pure Sine Wave < 3% THD | |||||||
Protection | Overload, Short Circuit, Reverse Polarity (Fuse), Input Undervoltage, Input Overvoltage, Over Temperature | |||||||
Digital Display | OVP, UVP, OTP, OLP, VAC, AMP, WATT, VDC, TEMP, Hz | |||||||
Safety | EN60950-1 | |||||||
EMC | FCC Class A | EN 55022:2006, Class A EN 61000-3-2: 2006 EN 61000-3-3: 1995+A1: 2001+A2: 2005 | ||||||
Interface Control Unit | RS-232C with Baud Rate 2400, 4800, 9600, 19200 (Switch Selectable) | |||||||
Remote Control Unit | Optional | Can’t support | Optional | Can’t support | ||||
AC Input | 110V AC | 220V AC | ||||||
AC Frequency | (50Hz ~ 60 Hz) ± 3% | (50Hz ~ 60 Hz) ± 3% | ||||||
Bypass | 4~6ms | 4~6ms | ||||||
Inverter mode or UPS mode by switch | ||||||||
Operating Temperature Range | -20°C to 50°C | |||||||
Storage Temperature Range | -30°C to 70°C | |||||||
Dimensions | 504(L) ×425(W) ×132(H) mm | |||||||
Cooling | Loading controlled cooling fan | |||||||
Weight | 19kgs |