19" UPS 2U2KVA rack-mount telecom power inverter
USD $700 - $2,000 /Unit
Min.Order:1 Unit
Features :
Pure sine wave output (THD < 3%) R load
Inverter mode or UPS mode
By pass function
Output frequency : 50/60Hz switch
RS-232 interface / remote controls port / Wire connection to PC
Optional : SNMP interface / DC input 110/220 / door / 5 sets dry contacts (voltage free)
Wired Remote control
Loading controlled cooling fan
Advanced microprocessor
Protection : Input Undervoltage, Input Overvoltage, Overload, Short circuit, Low battery alarm, Over temperature
AC output sockets : Universal / UK / SCHUKO / USA / Australia/New Zealand / Terminal / IEC
Specification | Model | ||||||||||||
Item | YK-UIPSW | YK-UIPSW | YK-UIPSW482KVA | YK-UIPSW | YK-UIPSW2202KVA | YK-UIPSW | YK-UIPSW242KVAE | YK-UIPSW482KVAE | YK-UIPSW1102KVAE | YK-UIPSW | |||
Continuous Output Power | 2000W | ||||||||||||
Surge Rating | 3Min. | 2300W | |||||||||||
3Sec. | 2500W | ||||||||||||
Peak | 4000W | ||||||||||||
Input Voltage | 12V | 24V | 48V | 110V | 220V | 12V | 24V | 48V | 110V | 220V | |||
Frequency | 50/60Hz ± 0.05% (Switch Selectable) | ||||||||||||
Output Voltage Adjustment | 100~120VAC(Tune VR) | 200~240VAC(Tune VR) | |||||||||||
Peak Output Current | 36A | 18A | |||||||||||
Efficiency | 86% | 88% | 90% | 94% | 94% | 87% | 90% | 92% | 94% | 94% | |||
No Load Current Draw | 1.45A | 0.7A | 0.45A | 0.38A | 0.18A | 1.47A | 0.8A | 0.47A | 0.4A | 0.2A | |||
Output Waveform | R Load Pure Sine Wave <3% THD | ||||||||||||
P.F. | 1.0 | 1.0 | |||||||||||
Input Voltage Regulation | 10-16 | 20-32 | 42-62 | 90-140 | 180-275 | 10-16 | 20-32 VDC | 42-62 | 90-140 | 180-275 | |||
DC Input over voltage alarm | 15.5VDC | 31VDC | 61VDC | 135VDC | 270VDC | 15.5VDC | 31VDC | 61VDC | 135VDC | 270VDC | |||
DC Input over voltage shut-down
| 16.0VDC | 32.0VDC | 62.0VDC | 140VDC | 275VDC | 16.0VDC | 32.0VDC | 62.0VDC | 140VDC | 275VDC | |||
DC Input under voltage alarm | 10.5VDC | 21.0VDC | 43.0VDC | 95VDC | 185VDC | 10.5VDC | 21.0VDC | 43.0VDC | 95VDC | 185VDC | |||
DC Input under voltage
| 10.0VDC | 20.0VDC | 42.0VDC | 90VDC | 180VDC | 10.0VDC | 20.0VDC | 42.0VDC | 90VDC | 180VDC | |||
Protection | Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Input Voltage, Over Temperature | ||||||||||||
Digital Display | OVP, UVP, OTP, OLP, VAC, AMP, WATT, VDC, TEMP, Hz | ||||||||||||
Safety | EN60950-1 | ||||||||||||
EMC | FCC Class A | EN 55022: 2006,Class A EN 61000-3-2: 2006 EN 61000-3-3: 1995+ A1:2001+A2:2005 | |||||||||||
Interface Control Port | RS-232 With Baud Rate 2400, 4800, 9600, 19200 (Switch Selectable) | ||||||||||||
Remote Control Unit | Optional | Can’t support | Optional | Can’t support | |||||||||
AC Input | 110V AC (90~130V) | 220V AC (180~260V) | |||||||||||
AC Frequency | (50Hz ~ 60 Hz) ± 3% | (50Hz ~ 60 Hz) ± 3% | |||||||||||
Bypass | 4~6ms | 4~6ms | |||||||||||
Inverter mode or UPS mode by switch | |||||||||||||
Operating Temperature Range | -20°C to 50°C
to 50℃ | ||||||||||||
Storage Temperature Range | -30°C to 70°C
| ||||||||||||
Dimensions | 435(L) ×424(W) ×88(H) mm | ||||||||||||
Weight | 12.8kgs |
Specification | Model | ||||||||||||
Item | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | |||
Continuous Output Power | 3000W | ||||||||||||
Surge Rating | 3Min. | 3200W | |||||||||||
3Sec. | 3500W | ||||||||||||
Peak | 6000W | ||||||||||||
Input Voltage | 12V | 24V | 48V | 110V | 220V | 12V | 24V | 48V | 110V | 220V | |||
Frequency | 50/60Hz ± 0.05% (Switch Selectable) | ||||||||||||
Output Voltage Adjustment | 100~120VAC (Tune VR) | 200~240VAC (Tune VR) | |||||||||||
Peak Output Current | 54A | 27A | |||||||||||
Efficiency | 86% | 88% | 89% | 94% | 94% | 87% | 90% | 92% | 94% | 94% | |||
No load Current Draw | 1.50A | 0.82A | 0.39A | 0.16A | 0.11A | 2.20A | 1.08A | 0.55A | 0.28A | 0.12A | |||
Output Wave form | R Load Pure Sine Wave < 3% THD | ||||||||||||
P.F. | 1.0 | 1.0 | |||||||||||
Input Voltage Range | 10-16 | 20-32 | 42-62 | 90-140 | 180-275 | 10-16 | 20-32 | 42-62 | 90-140 | 180-275 | |||
DC Input over voltage alarm | 15.5VDC | 31.0VDC | 61.0VDC | 135.0VDC | 270.0VDC | 15.5VDC | 31.0VDC | 61.0VDC | 135.0VDC | 270.0VDC | |||
DC Input over voltage shut-down | 16.0VDC | 32.0VDC | 62.0VDC | 140.0VDC | 275.0VDC | 16.0VDC | 32.0VDC | 62.0VDC | 140.0VDC | 275.0VDC | |||
DC Input under voltage alarm | 10.5VDC | 21.0VDC | 43.0VDC | 95.0VDC | 185.0VDC | 10.5VDC | 21.0VDC | 43.0VDC | 95.0VDC | 185.0VDC | |||
DC Input under voltage shut-down | 10.0VDC | 20.0VDC | 42.0VDC | 90.0VDC | 180.0VDC | 10.0VDC | 20.0VDC | 42.0VDC | 90.0VDC | 180.0VDC | |||
Protection | Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Input Voltage, Over Temperature | ||||||||||||
Digital Display | OVP, UVP, OTP, OLP, VAC, AMP, WATT, VDC, TEMP, Hz | ||||||||||||
Safety | EN60950-1 | ||||||||||||
EMC | FCC Class A | EN 55022: 2006,Class A EN 61000-3-2: 2006 EN 61000-3-3: 1995+ A1:2001+A2:2005 | |||||||||||
Interface Control Port | RS-232C With Baud Rate 2400, 4800, 9600, 19200 (Switch Selectable) | ||||||||||||
Remote Control Unit | Optional | Can’t support | Optional | Can’t support | |||||||||
AC Input | 110VAC(90~130V) | 220VAC(180~260V) | |||||||||||
AC Frequency | (50Hz ~ 60 Hz) ± 3% | (50Hz ~ 60 Hz) ± 3% | |||||||||||
Bypass | 4~6ms | 4~6ms | |||||||||||
Inverter mode or UPS mode by switch | |||||||||||||
Operating Temperature Range | -20°C to 50°C
| ||||||||||||
Storage Temperature Range | -30°C to 70°C
| ||||||||||||
Dimensions | 445(L) ×424(W) ×88(H) mm | ||||||||||||