ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder
ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder
ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder
ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder
ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder

ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder

USD $308 - $491.67 /Piece

Min.Order:1 Piece

Supply Ability:
0 per Month
Port:
guangzhou
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
ETCR
Model Number:
ETCR8300
Display Type:
Digital Only
Measuring Range:
0.0A~500A
Accuracy Class:
±2%±5dgt

Guangzhou ETCR Electronic Technology Co., Ltd.

Business Type: Manufacturer
Guangzhou Guangdong China
Main Products: Phase Detector ,Damp Resistance Tester ,Current Meter ,Current Sensor ,Soft Magnetic Alloy Core

Product Details

Specifications

Function: Testing three-channel Leakage current,on-line monitoring,line maintenance
Range: 0.0A~500A.
Resolution:0.1A

ETCR8300 Three Channel Leakage Monitoring Recorder

Product information

 ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder

 

ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder

Product Features

1. Monitoring three-channel AC leakage, current measurement, online monitoring, insulation fault detection, line maintenance

2. Ultra-large capacity: data storage for 3900sets;

3. RS232 interface data upload function

4. Patent [ZL 2008 2 0188823.1]

5. Long time continuously working: 240h

6. Automatic recording according the time have set within 1~99mins

7. Range: 0.0A~500A

 

 

ETCR8300 series Three-Channel Current/Leakage Monitoring Recorder is well designed and manufactured for online measurement, monitoring and recording of Three-Channel AC leakage / current at the same time. It is composed of a tester, monitoring software, current clamp and communication cable, etc. This instrument has been widely applied the 380/220 Power system. It can provide a safety and convenience measurement with accurate results.

 

     The instrument has a large LCD display with blue background and a large storage space. 3900 sets of data can be stored in the instrument. Three- channel current value can be display on the screen. In addition, the instrument can automatically store data at a interval, which is adjustable from 1 to 99 min.

 

Monitoring software provides online and real-time monitoring and historical data inquiry. With the software developed by our technical department, the users can read, inquire, store, generate and print a fitting curve and report.

 

     The current clamp is made of a special alloy, adopts the latest CT technique and magnetic shielding technique and is not almost interfered by external magnetic field. This ensures high accuracy, high stability and high reliability of the values which are measured continuously

 

 

Model Difference

Model

Range

Resolution

Channels

Clamp size

ETCR8000

0.0A~500A

0.1A

One Channel

35mm×40mm

ETCR8000B

0.00mA~20A

0.01mA

One Channel

25mm×30mm

ETCR8300

0.0A~500A

0.1A

Three-Channel

35mm×40mm

ETCR8300B

0.00mA~20A

0.01mA

Three-Channel

25mm×30mm

 

Technical Specifications 

Function

Measuring Three- channel AC leakage current and AC current, on-line monitoring and recording, locating insulation faults and repairing electrical lines.

Power Supply

DC6V, AA alkaline battery 1.5V×4

Test Method

Clamp CT, TRMS

Range

0.0A-500A

Resolution

0.1A

Accuracy

±2%±5dgt

Clamp size

35mm×40mm

Dimension of Clamp

122×70×33(mm)

Display

LCD:128dots×64dots;Display:44mm×27mm

Dimension

Tester(LWH): 75mm×170mm×30mm

Mass

750g(with batteries)

Shield

Single layer shielding

Sample Rate

2 samples/s

Data storage

3900 sets (data loss does not occur after power failure or replacing the battery)

Time Setting

Recording internal adjustable from 1 to 99 min, If set to 0 min, the auto-store function is turned off

Record Time

Continuously operate for about 10 days at the power-saving mode

Line Voltage

Below AC600V

Overflow

The “OL” symbol is displayed when a measured value is beyond the measurement range

Battery Voltage

A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate.

Rated Power

About 5mA at the power-saving mode, maximum current consumption: 20mA

Lead Length

2m

Environment

-20~50;below 80%rh

Insulation Resistance

Higher than 100MΩ, 1000V

Safety Codes

IEC1010-1, IEC1010-2-032, Pollution Degree: 2;  CAT (600V), IEC61326(EMC standard)

Accessories

Tester:1pc, Clamp:3pcs, Bag:1pc, RS232 line:1pc;  Disk:1pc

Packing

Packing Size: (L ×W ×H): 235× 210×70(mm)

Weight: 1.1Kg

Company information

ETCR

A professional manufacturer of test and measure instrument
We have our research and development, top sales group, supply application services
ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder has become well-known brand
ETCR Help you work safer and faster
There will be professional responsible for after sale service
We are developing international market
So every customer's identity is our best encouragement
Our buyers have stayed with us for 12 years
ISO Patentand CE certificate 
OEM services available
 

More information, please kindly view our web site: /en/

Online store: /store/1119041  

ISO CE ETCR8300 Three Channel Leakage Monitoring RecorderISO CE ETCR8300 Three Channel Leakage Monitoring Recorder 
Certifications

ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder

Attention

ISO CE ETCR8300 Three Channel Leakage Monitoring Recorder

 

 

 

 

Contact Supplier

Ms. Lili Su Sales Manager Chat Now
Telephone
86-020-62199556
Mobile
13802922567
Fax
86-020-62199550
Address
F-3F,No.4 Pengshang Zhifu Road, Jiahe,Baiyun District,Guangzhou,Guangdong,China. Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Current Meters
Categories
Hi~