ETCR9300B Low Voltage Current Transformation Ratio Tester
USD $432 - $600 /Piece
Min.Order:1 Piece
Guangzhou ETCR Electronic Technology Co., Ltd.
ETCR9300B Low Voltage Current Transformation Ratio Tester
.
. Introduction
ETCR9300B Low Voltage Current Transformation Ratio Tester can widely applied in 380V/220V electric power system, for conveniently and fast online measurement of current transformer in measurement devices, and measurement of current and leakage current in 380V/220V electric power system. Without power cut, it can also accurately measure the current transformation ratio, ratio difference, angle difference, phase, polar. Provide operators with a safe, accurate and convenient tester. Its application will bring remarkable economic and social benefits in power supply management for electric power enterprise.
. Technical Specification
Function | Measurement of current, transformation ratio, ratio difference, angle difference, phase, polar of primary/secondary circuit of low voltage current transformation. |
Power Supply | DC6V alkaline dry battery (1.5V AAA×4) |
Test Mode | ClampCT |
Display Mode | LCD: 128dots×64dots; Blue screen, backlight, suitable for dark places |
LCD Size | Display area: 44mm×27mm |
Dimension | Width × Height× Thickness: Main tester: 75mm×170mm×30mm Primary current clamp: 40×138×20mm Secondary current clamp: 115×70×33mm |
Clamp Size | Primary current clamp: 80×80mm; Secondary current clamp: 25×30mm |
Measurement Range | Primary current clamp: 0.00mA-1000A; Secondary current clamp: 0.00mA-10A |
Resolution | Primary current clamp: 0.01mA; Secondary current clamp: 0.01mA |
Transformation Ratio | 1:10 million (1.0K7) |
Measuring Accuracy of the Primary Circuit | ±1%±3dgt (23°C±3°C, below 80%RH) |
Measuring Accuracy of the Secondary Circuit | ±0.5%±3dgt (23°C±3°C, below 70%RH) |
Sample Rate | 2 times/second |
Gear Shift | Automatic shift |
Data Storage | 3000 sets, press HOLD key, the data will be stored automatically with serial numbers (The data won’t be lost in case of lost power or replace battery) |
Circuit Voltage | Below AC 600V |
Data Hold | Press HOLD key, HOLDsymbol appears, press HOLD again to cancel. |
Data Read | Press HOLDkey and POWER key to access data reading. |
Overflow Display | “OL”symbol appears |
Automatic Power Off | Automaticallypower off about 15 minutes after power on to reduce battery consumption |
Battery Voltage | Low battery symbol appears to remind the replacement of battery when the battery voltage drops below 4.8V. |
Weight | 1200g |
External Interference | No strong electric and magnetic interference |
Working Temperature & Humidity | -25°C-45°C, below 80%Rh |
Length of Lead Wire | Standard 2m (Can be extended to max 50m according to practical situation.) |
Insulation strength | AC 3700V/rms (between core and shell) |
Accessories | Main tester: 1PC; Primary current clamp: 1PC; Secondary current clamp: 1PC; Meter box: 1PC; Battery (alkaline dry battery AAA): 4PCS |
. Field Application