Heat Pump Water to Water

Heat Pump Water to Water

USD $2,000 - $25,000 /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Port:
QINGDAO PORT
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Type:
Water Source Heat Pump
Installation:
Freestanding
Storage / Tankless:
Instant / Tankless
Housing Material:
Stainless Steel
Use:
Bathroom
Certification:
CB, CE, CSA, EMC, EMF, GS, LFGB, Other, SASO, UL, UR, CB, CE, CSA, EMC, EMF, GS, LFGB, RoHS, SASO, UL, UR, ISO CERTIFICATE

Shandong Lvte Air Conditioning System Co., Ltd.

Business Type: Manufacturer,Trading Company
Weifang Shandong China
Main Products: Air Conditioning and Refrigeration Products Heat pump ,Chiller ,Fan coil ,Air handling unit ,Condensing unit ,Evaporator ,Condenser ,Compressor racks

Product Details

Specifications

Heat Pump Water to Water
1.7-250KW Cooling Capacity
2.Kinds of Heat Exchanger
3.R22,R134a,R407C,R410a
4.High Efficiency

HEAT PUMP WATER TO WATER

Product Description

 

Heat Pump Water to Water Introduction:

APPLICATION

Used to be central air conditioning for an area of 100m2~ 1000m2 building. It can also providing free living hot water for demand as Villa, hotel, restaurant, factory, theater, stadium, residential quarter, textile, food, medicine, metallurgy etc;

STRUCTURE

Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents;

HERMETIC COMPRESSORS

Use brand hermetic scroll compressor with built-in thermal overload cut-out and crankcase heater mounted on rubber vibration dampers. With low energy consumption, stable operation, and little vibration and low noise;

EVAPORATOR

High efficiency tube in tube or plate heat exchanger, factory insulated with flexible close cell material;

CONDENSER

High efficiency tube in tube or plate heat exchanger, factory insulated with flexible close cell material;

REFRIGERANT CIRCUIT

Copper tube connection with charge valves, filter, thermostatic expansion valve, liquid receiver, high pressure switch and low pressure switch; The heat pumps are completely also with 4-way valve and one way valve;

HYDRAULIC CIRCUIT

Built with user side and source side water inlet-outlet connectors, water discharge connectors;

ELECTRIC PANEL

Compressor contactor;

Compressor protection breaker;

User side water pump contactor (mod.2÷10);

User side water pump breaker (mod. 2÷10);

Microprocessor with function display.

OPTIONAL

Sight glass which must be installed in factory;

Source side water flow switch;

Source side water pump;

Anti-vibration rubber;

Metallic filter for the water circuit;

Desuperheater(Heat Recovery) as optional.

Heat Pump Water to Water 

 

Heat Pump Water to Water Model Specification:

LT W H (R) --2 C P H

LT-Company Products Code

W-Compressor Type; W: Scroll Compressor/P: Piston Compressor

S: Water to Water Type

R-Unit Type; R: Heat Pump

2-Normal Cooling Capacity (Tons)

C-Refrigerant Type; -:R22/ A: R407C/ B: R134A/ C:R410a

P: Plate Heat Exchanger/ T:Tube in Tube Heat Exchanger/ S: Shell and Tube Heat Exchanger

--: Standard version/ H: with partial heat recovery/ Q: with total heat recovery

Heat Pump Water to Water

 

Heat Pump Water to Water

Remark:

1.Cooling Condition:Chilled water (User Side) in/out 12/7; Cooling water (Source Side) in/out 18/29;

Source Side is based on Groundwater; if the closed loop soil source, please contact;

2.Heating Condition:Hot water (User Side) in/out 40/45; Cooling water (Source Side) in/out 15/7;

Source Side is based on Groundwater; if the closed loop soil source, please contact;

3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;

other requests as 220V, 60HZ please contact;

4.The data above is for R407C, contact us if that for R134a, R22, R10a and other refrigerant need;

5.The size is based on Scroll Compressor, Plate Heat Exchanger; others please contact;

6.If used to be water heater; R410a,R22,R407C max. hot water 55; R134a Max. Hot Water 65;

7.There may be Changes for improvement without notice, confirm always before your order.

 

Geothermal Heat Pump heating and Cooling SYSTEM: Close loop or open loop geothermal heating and cooling system with heat recovery for hot sanitary water; the terminal is floor heating or fan coil heating and cooling.

Ground/Water source heat pump system can adopt water of lake, river, and underground and ground heat source; With compressor and electrical power, it can transmit heat from water into the room in winter, and from room into water in summer to achieve the purpose of air conditioning. Heat from the ground is absorbed at low temperatures into a fluid inside a loop of pipe (a ground loop) buried underground. The fluid then passes through a compressor that raises it to a higher temperature, which can then heat water for the heating and hot water circuits of the house. The cooled ground-loop fluid passes back into the ground where it absorbs further energy from the ground in a continuous process as long as heating is required.

Normally the loop is laid flat or coiled in trenches about two metres deep, but if there is not enough space in your garden you can install a vertical loop down into the ground to a depth of up to 100 metres for a typical domestic home.

Heat Pump Water to WaterHeat Pump Water to Water 

 

Heat Pump Water to Water Advantages:

Environmental-friendly:

In heating mode, it can replace the boiler system to avoid smoke-pollution. In cooling mode, it can avoid noise and leaf mold from cooling tower to protect environment.

Energy saving:

In winter, user can get 5KW heat power with 1kw electrical power. In summer, uses can get more than 6KW cooling power with 1kw electrical power. The efficiency is 3-4 times as that of electrical heater.

Space-saving:

No need of Boiler and relevant equipment, by which can save space.

Water-Saving:

Cooling or heating can be realize by discharging or absorbing power into the water; water source will not be consumed neither be polluted.

Money-saving:

Cooling or heating can be realized by one system; its investment is 1/2-2 of that of traditional equipment.

Heat Pump Water to Water

 

HEAT PUMP WATER TO WATER CERTIFICATE:

Heat Pump Water to Water

 

 

Company Information

Founded in 2002, located in International Kite Capital Weifang City, Near Beijing and Qingdo Port. We are professional manufacturer of HVAC Equipments including Chiller (Air Cooled Chiller, Water Cooled Chiller, Water Chiller), Heat Pump (Water to Water Heat Pump, Air to Water Heat Pump, Water Source Heat Pump, Air Source Heat Pump, Ground Source Heat Pump, Geothermal Heat Pump), Fan Coil Unit (Duct Fan Coil, Ceiling Fan Coil, Cassette Fan Coil, Floor Fan Coil), Air Handling Unit (AHU, Ceiling and Cabinet AHU), New Air Heat Exchange Units etc. and Refrigeration Equipments and Parts including Condensing Unit (Copeland, Bitzer, Danfoss Units etc), Evaporator, Condenser, Compressor Racks etc for cold storage, freezer, blast freezing. Our products have rewarded of CE, ISO, UL, BV etc international certificate.

We have the advantages:

Quality Assurance

Excellent After-sales Service

Professional Technical Teams

Delivery on Time

Communication in Time

Competitive Prices

So welcome to inquiry us anything you want.

 

 

 

 

 

Contact Supplier

Mr. Jack Jin Marketing Director Chat Now
Telephone
86-536-2119006
Mobile
0086 15094977989
Fax
86-536-2257000
Address
No. 3999, South Airport Road, Weicheng District Weifang,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Home Appliances > Water Heaters > Heat Pump Water Heaters
Categories
Hi~