T W330 portable thermocouple indicator
USD $400 - $450 /Set
Min.Order:1 Set
Cangzhou Qirun Detecting Instrument Co., Ltd.
The Usage:
The W330 portable thermocouple indicator is connected with the thermocouple used for monitoring the temperature of molten metal for melting and casting.
This instrument by the high performance of a single-chip computer as the core, the high precision accuracy measuring transducer parts, and take multiple intelligent processing technology, to ensure the long-term stability instrument. Improve the anti-interference ability of the instrument.
Matching 5 type thermocouple.
Thermocouple type | Model | Measurement range(°C) | Application |
PtRh10%-Pt | KS-602 | 0~1750 | Liquid Steel/Iron/Copper |
PtRh13%-Pt | KR-602 | 0~1750 | Liquid Steel/Iron/Copper |
PtRh30%-Pr-Rh6% | KB-602 | 500~1800 | High temperature Molten steel |
WRe3%-WRe25% | KW-602 | 0~2000 | Molten steel/Iron |
NiCr-NiSi | K | 0~1000 | Molten Aluminum/Zinc |
Feature:
1.Automatic save measuring temperature records
2.Acousto-optic to suggest you the measuring over.(When you hold the lance)
3. It has the function of fault alarm for power line broken,bad connect and overrange .
4.Power adopt nickel metal hydride rechargeable batteries( One charging time,the Lance can used 1000 times )
5.Automatic two minutes after the power input signal no
6.Strong anti-jamming ability
Technical performance target
1Measurement range and accuracy of measurement
Type | Measurement range(°C) | Accuracy |
S | 0~1750 | ≤±0.2%±1°C |
R | 0~1750 | |
WRe3/25 | 0~2000 | |
B | 500~1800 | |
K | 0~1000 |
2.resolution (°C):1
3response time(S):1
4environmental condition
(1)working condition: Temperature(°C):0-50; Humidity(%RH):5-80
(2)storage condition:Temperature(°C)-20-60; Humidity(%RH):5-90
5Power: DC6V±10%(rechargeable Ni/MH battery)
Working principle
W330 type indicator is a sensor to connect with sensor.
Thermocouple temperature measurement is generated when the electric potential after instrument preamplifier device, and then after A/D converter converted into digital quantity, let into the data processing in the computer, and realize the environment temperature automatic compensation, zero since calibration, furnace temperature stable value is automatically and keep.
This instrument is over, when measured with a light, sound synchronous tip measurement buzzer is over, display temperature measurement, and keep a value measurement for a time.
Install or operate
1.Install
A The indicator
B Screw
C The Lance
D The Thermocouple plug
E The plug in the socket must put it to the end