professionally manufactured durable 100w dc transformer 220v ac to 24v dc, 220v 7.5v transformer
USD $8 - $9 /Piece
Min.Order:10 Pieces
Yueqing Hupsun Import And Export Company Limited
professionally manufactured durable 100w dc transformer 220v ac to 24v dc, 220v 7.5v transformer
OEM welcome
Low price and high reliability
105Celsius degree output capacitor
Universal AC input
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With short-circuit and overload protection
Compact size,light weight
100% full-load burn-in test
Install with EMI filter,minimum wave
Model&Specification | S-100-3 | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-24 | S-100-27 | S-100-48 |
DC Output voltage | 3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 48V |
Output voltage range(Note:2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 20A | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 3.7A | 2A |
Output current range | 0~20A | 0~20A | 0~13.6A | 0~8.5A | 0~6.7A | 0~4.5A | 0~3.7A | 0~2A |
Wave and noise(Note:3) | 75mVp-p | 75mVp-p | 70mVp-p | 60mVp-p | 60mVp-p | 50mVp-p | 50mVp-p | 50mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load stability(Note:5) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
DC output power | 60W | 100W | 102W | 102W | 100.5W | 108W | 100W | 96W |
Efficiency | 74% | 78% | 80% | 82% | 82% | 85% | 86% | 86% |
Adjustable range for DC voltage | 2.85~3.3V | 4.75~5.5V | 6.75~8.25V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | 26~32V | 43.2~52.8V |
AC input voltage range | 85~132VAC/180~264VAC selected by switch 47~63Hz,255~370VDC | |||||||
Input current | 2.4A/115V 1.2A/230V | |||||||
AC Inrush current | Cold-start current 30A/115V 60A/230V | |||||||
Leakage current | <1mA/240VAC | |||||||
Overload protection | 105% ~ 150% | 105% ~ 200% | 105% ~ 150% | |||||
Type: pulsing hiccup shutdown Reset: Recycled AC ON/OFF | ||||||||
Temperature coefficient | ±0.03%/°C(0~50°C) | |||||||
Setup, rise, hold up time | 200ms, 100ms, 30ms | |||||||
Vibration | 10~500Hz, 2G 10min,/1 cycle. Period for 60min,Each axes | |||||||
Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||||
Working temperature humidity | -10°C~+60°C(Refer to output derating curve), 20%~90%RH | |||||||
Store temperature and humidity | -20°C~+85°C, 10%~95%RH | |||||||
Overall dimension | 199*98*38mm (L*W*H) | |||||||
Weight | 0.57Kg | |||||||
Safety standards | Meet UL1012 requirement(Not apply for the mark) | |||||||
EMC standards | Meet FCC PART 15J Conduction class B | |||||||
Note: 1. The parameter under the testing condition: 230VAC input, rated load, 25°C70% RH. Temperature. |