best selling products cheap wholesale good quality source 12v 5a 60w power supply 12 volts 5 amps
USD $6 - $7 /Piece
Min.Order:10 Pieces
Yueqing Hupsun Import And Export Company Limited
best selling products cheap wholesale good quality source 12v 5a 60w power supply 12 volts 5 amps
OEM welcome
Low price and high reliability
105Celsius degree output capacitor
Universal AC input
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With short-circuit and overload protection
Compact size,light weight
100% full-load burn-in test
Install with EMI filter,minimum wave
Model&Specification | S-60-5 | S-60-12 | S-60-15 | S-60-24 |
DC Output voltage | 5V | 12V | 15V | 24V |
Output voltage range(Note:2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 12A | 5A | 4A | 2.5A |
Output current range | 0~12A | 0~5A | 0~4A | 0~2.5A |
Wave and noise(Note:3) | 100mVp-p | 75mVp-p | 75mVp-p | 75mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note:5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 60W | 60W | 60W | 60W |
Efficiency | 73% | 78% | 78% | 82% |
Adjustable range for DC voltage | +10,-5% | ±10% | ±10% | ±10% |
AC input voltage range | 85~132VAC/170~264VAC selected by switch 47~63Hz,240~370VDC | |||
Input current | 2A/115V 1A/230V | |||
AC Inrush current | Cold-start current 30A/115V 60A/230V | |||
Leakage current | <3.5mA/240VAC | |||
Overload protection | 105%-150% Type: pulsing hiccup shutdown Reset: auto recovery | |||
Temperature coefficient | ±0.03%/°C(0~50°C) | |||
Setup, rise, hold up time | 800ms, 50ms, 10ms/150V 300ms,50ms,80ms/230v | |||
Vibration | 10~500Hz, 2G 10min,/1 cycle. Period for 60min,Each axes | |||
Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||
Working temperature and humidity | -10°C~+60°C(Refer to output load derating curve),20%~90%RH | |||
Store temperature and humidity | -20°C~+85°C,10%~95%RH | |||
Overall dimension | 159*97*38mm (L*W*H) | |||
Weight | 0.55kgS | |||
Safety standards | UL 1012 TUV EN6050(IEC,ul1950)Approved | |||
EMC standards | CISPR22(EN55022),IEC801-2,3,4 IEC555-2Verification | |||
Note | 1. The parameter under the testing condition : 230vAC input ,rated load,25°C70% RH. Temperature. 2. Tolerance the setting tolerance, circuit stability and load stability.(Note:5). 3. Wave test: adopting "A12"double wire for 20MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test : the lowest voltage will be up to the highest voltage when the circuit overload. 5. Load stability test: The load is from 0% to 100%. |