Medium temperature cold room evaporative air cooler for condensing unit with three motors
USD $800 - $1,500 /Set
Min.Order:2 Sets
Hangzhou Yemoo Refrigeration Equipment Co., Ltd.
YEMOO -18 degree cold room air cooler mini chiller air cooler for fruit storage
YEMOO DD series plate type evaporator ceiling type small evaporator from manufacturer
YEMOO 11.4KW cold room cooling system small refrigeration air evaporator for food storage
YEMOO DD series heat exchanger evaporator two motors cold room evaporator for fruit storage
YEMOO -25 degree industrial refrigeration parts small evaporative air cooler best price on sale
YEMOO DJ series chiller evaporator ice maker evaporator for cold room food storage
Evaporative Air Cooler/Air cooled Evaporator For Cold Room
DL DD DJ series for your choice
DL : High temperature
DD : Medium temperature
DJ : Low temperature
Characteristics
1.Scientific structure cold room evaporative air cooler, high efficient, frost steadily, save power and low running cost;
2.Cold room evaporative air cooler is equipped with axial fan quiet models that offer strong air flow in long shot rang; save power, long service life;
3.Copper pipe thickness can reach to 0.6mm, which lead to perfect tightness between pipe and fin after expansion processing;
4.Cold room evaporative air cooler is equipped with stainless electric heater in high insulating property, defrost efficiently in shot time;
5.The heat exchanging coil was did gas tightness test under 2.6MPa air pressure, to guarantee quality.
6.Aluminum and painted stain board, to meet your different needs.
Sphere of application
High temperature type small air cooler :(cold room temperature 12~-2oC)fin space:4.5mm;
Medium temperature type small air cooler :(cold room temperature-2~-10 oC) fin space:6.0mm;
Low temperature type small air cooler : (cold room temperature-10~-31 oC)fin space:9.0mm;
Attention of small air cooler model selection
When the cold-room temperature is aroud 0 oC, select 8 oC to be the difference between compressor evaporating temperature and cold-room temperature.
when the cold-room temperature is aroud -18 oC select 7 oC to be the difference between compressor evaporating temperature and cold-room temperature.
when the cold-room temperature is aroud -25 oC, select 6 oC to be the difference between compressor evaporating temperature and cold-room temperature.
According to selected evaporating temperature, compressor’s capacity = the cold-room loading × 1.15.
Model | Ref. capacity(KW) | Cooling surface (m2) | Fan | Defrost heater | Remark | |||||||
Qty | Diameter Φ(mm) | Air flow (m2/h) | Air pressure (pa) | Shot range (m) | Power (W) | Coil (kW/PC) | Drip pan (kW) | Voltage (V) | ||||
DD-012B | 2.2 | 12 | 2 | 300 | 2×2118 | 90 | 10 | 2×145 | 0.36×4 | 0.36x2 | 380 | Water-defrosting type and customized are optional |
DD-015B | 2.8 | 15 | 2 | 300 | 2×2118 | 90 | 10 | 2×145 | 0.41×4 | 0.41x2 | 380 | |
DD-022B | 3.7 | 22 | 2 | 350 | 2×2290 | 90 | 10 | 2×140 | 0.58x4 | 0.58x2 | 380 | |
DD-030B | 5.7 | 30 | 2 | 350 | 2×2290 | 90 | 10 | 2×140 | 0.49x6 | 0.49x2 | 380 | |
DD-040B | 7.5 | 40 | 2 | 400 | 2×3400 | 90 | 13 | 2×180 | 0.51x8 | 0.51x2 | 380 | |
DD-060B | 11.4 | 60 | 2 | 500 | 2×6570 | 90 | 15 | 2×450 | 0.61x8 | 0.61x2 | 380 | |
DD-080B | 15.2 | 80 | 2 | 500 | 2×6570 | 90 | 15 | 2×450 | 0.81x8 | 0.81x2 | 380 | |
DD-100B | 18.7 | 100 | 3 | 500 | 3×6570 | 90 | 15 | 3×450 | 0.83x9 | 0.83x3 | 380 | |
DD-120B | 22.4 | 120 | 3 | 500 | 3×6570 | 90 | 15 | 3×450 | 1.0x9 | 1.0x3 | 380 | |
DD-140B | 26.2 | 140 | 4 | 500 | 4×6570 | 90 | 15 | 4×450 | 1.1x9 | 1.1x3 | 380 | |
DD-160B | 30 | 160 | 4 | 500 | 4×6570 | 90 | 15 | 4×450 | 1.1x11 | 1.1x3 | 380 | |
DD-200B | 37.4 | 200 | 3 | 550 | 3×8720 | 90 | 15 | 3×600 | 1.2x13 | 1.2x3 | 380 | Axial fan |
DD-250B | 46.8 | 250 | 4 | 550 | 4×8720 | 90 | 15 | 4×600 | 1.1x15 | 1.1x3 | 380 | |
DD-300B | 56.2 | 300 | 4 | 600 | 4×10820 | 120 | 15 | 4×780 | 1.3x15 | 1.3x3 | 380 | |
Remark | Cold room temp. -18oC ; t=7oC |
Model | L | W | H | Installation size | Water tube (inch) | Connecting tube Φ(mm) | Weight (kg) | ||||||
B | T | H | L | E1 | E2 | E3 | E4 | F | Inlet | Outlet | |||
DL-016B | 830 | 480 | 570 | 420 | 510 | / | / | / | 135 | 3/4 | 12 | 22 | 35 |
DD-012B | 34 | ||||||||||||
DJ-008B | 49 | ||||||||||||
DL-020B | 830 | 480 | 670 | 420 | 520 | / | / | / | 130 | 3/4 | 12 | 22 | 38 |
DD-015B | 37 | ||||||||||||
DJ-010B | 36 | ||||||||||||
DL-030B | 1230 | 480 | 570 | 420 | 910 | 455 | / | / | 135 | 3/4 | 12 | 22 | 50 |
DD-022B | 49 | ||||||||||||
DJ-015B | 48 | ||||||||||||
DL-040B | 1400 | 380 | 570 | 340 | 1080 | 540 | / | / | 135 | 1 | 16 | 28 | 57 |
DD-030B | 56 | ||||||||||||
DJ-020B | 54 | ||||||||||||
DL-055B | 1450 | 380 | 670 | 340 | 1130 | 565 | / | / | 130 | 1 | 16 | 28 | 68 |
DD-040B | 67 | ||||||||||||
DJ-030B | 66 | ||||||||||||
DL-080B | 1700 | 470 | 670 | 430 | 1370 | 695 | / | / | 130 | 1 | 16 | 35 | 96 |
DD-060B | 95 | ||||||||||||
DJ-040B | 94 | ||||||||||||
DL-105B | 2200 | 470 | 670 | 430 | 1890 | 945 | / | / | 130 | 1 | 22 | 50 | 114 |
DD-080B | 113 | ||||||||||||
DJ-055B | 112 | ||||||||||||
DL-135B | 2250 | 570 | 670 | 530 | 1938 | 646 | 646 | 130 | 1.5 | 22 | 50 | 143 | |
DD-100B | 142 | ||||||||||||
DJ-070B | 141 | ||||||||||||
DL-160B | 2750 | 570 | 670 | 530 | 2440 | 813 | 813 | / | 130 | 1.5 | 22 | 50 | 179 |
DD-120B | 178 | ||||||||||||
DJ-085B | 177 | ||||||||||||
DL-185B | 3000 | 570 | 670 | 530 | 2688 | 672 | 672 | 672 | 130 | 1.5 | 25 | 50 | 214 |
DD-140B | 213 | ||||||||||||
DJ-100B | 212 | ||||||||||||
DL-210B | 2900 | 570 | 670 | 530 | 2588 | 647 | 647 | 647 | 130 | 1.5 | 25 | 50 | 225 |
DD-160B | 224 | ||||||||||||
DJ-115B | 223 | ||||||||||||
DL-260B | 3200 | 620 | 770 | 570 | 2889 | 963 | 963 | / | 130 | 1.5 | 25 | 50 | 261 |
DD-200B | 260 | ||||||||||||
DJ-140B | 258 | ||||||||||||
DL-330B | 3000 | 720 | 770 | 690 | 2700 | 675 | 675 | 675 | 125 | 2 | 25 | 50 | 320 |
DD-250B | 317 | ||||||||||||
DJ-170B | 315 | ||||||||||||
DL-400B | 3400 | 720 | 770 | 690 | 3100 | 775 | 775 | 775 | 125 | 2 | 25 | 54 | 360 |
DD-300B | 359 | ||||||||||||
DJ-210B | 357 |
How to choose good quality evaporative air cooler?
1. Look at appearance. More smooth and beautiful appearance, higher integrated manufacturing. Even though beautiful products are not high quality, but high quality products must be beautiful. So that when we choose, we could attach the equipment surface and feel whether exists wound, uneven surface, distortion and so on phenomenon, or whether exists uneven distribution pigment, has spot, aerosol and bubble defects. Stainless material is one of better materials.
2. See the process. Machines of German are famous of excellent production process. Production and process technology is not only embodied the operation condition of product, but also shows the work attitude of enterprise. So that when we choose, we could see whether junctions are closely contact, whether widget is exquisite and so on.
3. See the parts. Complete machine is made of some parts, the quality of parts influences operation life and effect of machine. So that seeing the main part is the most important when we choose.
How to install evaporative air cooler?
For evaporative air cooler, it could be installed on the wall or the roof, but the premise must be sure that surrounding should be fresh and smooth, you must not choose bad environment such as kitchen, toilet and so on. Sometimes you need to install special exhauster machine if there are not enough doors and windows in cold room, the air displacement should be reached more than 80% or 90% of total air supplying of evaporative air cooler.
For install position, its rack structure bear weight is the weight of evaporative air cooler plus the weight of outlet air supply pipe plus the weight of maintainer.
To avoid rain leakage, pay attention to the work of pipe seal waterproof between indoor and outdoor when installing.
Air supply pipe should match the evaporative air cooler model, it must be designed according to the actual installation environment and number of outlet. (Common long pipe could adopt variable diameter way.)
In general case, you should as far as possible shorten the designed pipe and reduce branch in order to minimize the wind resistance and noise.
On the whole, it is the best choice to install evaporative air cooler on the middle, as far as possible reduce wind resistance and shorten installation pipe; Install the evaporative air cooler in dominant wind direction of cool environment if the condition allows.
How to maintain evaporative air cooler?
1. Often leak detection about evaporator. Leakage is a common fault phenomenon of evaporator, so that we should often leak detection.
When ammonia evaporator leaks, there is a pungent odor, there is no frost on funneled place. You also could se phenolphthalein test paper to check funneled place, because ammonia is alkaline, it will become to red color if encounter phenolphthalein test paper.
When Freon evaporator leaks, firstly see whether evaporation discharge tube has oil stains, because Freon could be dissolved with oil, oil will be bleed out with freon when freon leaks.
2. Often check the frosting condition of evaporator. When frost layer is thick, defrosting should be on time.
3. If do not use evaporator a long time, the pressure of evaporator should keep at 0.05Mpa.
1.We are Professional factory to make semi-hermetic compressor, condensing unit, evaporator and condenser more than 10 years.
2.We insist on innovation,purchasing the international quality materials,strong technique support,strictly control the production.
3.We firmly believe quality first,perfect production responsibility system.
4.We promise all Yemoo brand products,we supply 3 months new products guarantee replacement,12 months quality guarantee service.
So,what Yemoo can support you ? It's best price ratio products,perfect after-sales service guarantee.
Yemoo's value is what we supply you is not only products,but also creating you most value.