EN54-2:2003
EN54-4:2003
Designed for centralized and stand-alone protection of various applications against fires by controlling statuses of up to 16 fire alarm loops.
FEATURES:
- The panel has the module structure enabling to develop various performances on customer’s demand.
- The panel incorporates:
-Main control PCB with standard outputs: “Fault”, “Light”, “Sound” and “Norm”, “Alarm” auxiliary outputs;
-Keypad and indicators,
-Power supply PCB,
-One (ARTON-16F) 16 loop input/output units with 8 programmable outputs in each of them.
-BR4-8 blocking relay (8 signaling relays).
-BSKT-2 GSM communicator (according to order conditions).
-BSKM-2 phone communicator (according to order conditions).
-Remote output units with 24, 48, 72, 96 channels (according to order conditions).
-BSPC-2 computer coupler (according to order conditions).
- CAN2.0B high-speed industrial interface implements unit-to-unit communications.
- Various AL process algorithms enabling to set processing parameters individually for each AL:
-AL type: active, passive, combined;
-Recording the “Fire” status when: one detector/two detectors/one detector with verification triggers;
-Reset time;
-Expectation time of readiness after resetting;
-Expectation time of repeated triggering in verification mode;
-Threshold current of determination of detectors’ activation in AL (separately for passive and active detectors);
- Test mode can be set individually for each AL, in which alarm or emergency AL statuses will not be transmitted to a central monitoring station;
- All outputs of the panel have continuity control and issue messages about open-circuits or short-circuits in load circuit and can commutate currents up to 300 mA;
- Various algorithms of outputs’ operation enabling users to set the following parameters individually for each output:
Inversion;
-Active status time;
-Passive status mode (dynamic – flashing, with individual setting of enablement/ disablement -periods, or quiescent – steady state);
-Active status mode (dynamic- flashing, with individual setting of enablement/ disablement periods, or quiescent – steady state);
-Allowing enabling at short-circuit;
-Allowing enabling at open-circuit;
-Time of transitional processes in load circuit;
- The test mode can be set individually for each output, the output status will not be transmitted to a central monitoring station and the output will not be enabled physically
- Keypad and indicators block contains 4 lines x 40 characters LCD indicator enabling to display sufficient amount of necessary information, keypad with additional functional buttons, pop-up menu with the most usable functions that substantially facilitates the user’s work with the panel.
- Individual name can be entered for each zone and each output up to 16 characters long which can be used displaying information about the object on the indicator.
- The panel logs and records system events to energy-independent memory in tie with real time clocks, and also their following displaying on a LCD indicator or on interface. The log is counted on 60000 event records.
- Using the BSPC-2 you can review the current configuration and program (configurate) the panel from the inbuilt keypad or from computer.