pedometer with lanyard/data memory
USD $2 - $2.3 /Piece
Min.Order:100 Pieces
pedometer with lanyard
Functions:
-Step count.
-Count distance walked and calorie burned.
-Time display,12/24h mode.
-Alarm function.
-Fat Analyzer.
-5 groups data memory.
Time mode using instructions:
1.After switching on,the system enters full screen display mode with “BIBI” sound, then comes to Time mode with display 0:00.
2.Press triangle button,the system will be shift between 12/24 hours systems,“PM” logo will be shown when it is in 12 hours system.
3.Press“SET” button for 2s to set up hour,press triangle /inverted triangle
button canadd/reduce hours. The hours will add/reduce quickly if keep pressing.
4.Press“SET” again can set up minute,press triangle /inverted triangle
button can add/reduce hours. The minutes will add/reduce quickly if keep pressing.
5.Press“SET” button again to quit time settings.
Alarm clock mode using instructions:
1.Press M(MODE)toenter the alarm clock mode (with ALM mark).
2.Press triangle button to switch on/off the alarm clock. “ ”symbol will be shown when the alarm is switched on and disappear when switched off.
3.Press“SET” button for 2s to set up hour for alarm clock,press triangle /nverted triangle
button canadd/reduce hours. The hours will add/reduce quickly if keep pressing.
4.Press“SET” again can set up minute for alarm clock,press triangle /inverted triangle
button can add/reduce hours. The minutes will add/reduce quickly if keep pressing.
5.Press set, quit alarm display.
5 groups data memory mode:
Press “M”(MODE)button to enter fat analyzer mode.
1.Press triangle button ,the next group data will be display.
2.Press inverted triangle
button, the existing data of weight,height,age and stride will be shown.for example :
1)Press set for 2s to set up weight, press triangle /inverted triangle
button can add/reduce weight, The weight will add/reduce quickly if keep pressing.
Default metric system weight:50KGS. Imperial system:110LB
Weight range: Metric system:10-250 KGS, it will be added or reduced 0.5KG for one time. Imperial system:22-550LB, it will add or reduce1LB for press each time press.
2)Press "SET" to enter into height mode to set up height, press triangle /inverted triangle
button can add/reduce height, and will add/reduce quickly if keep pressing.
Default metric system height:165CM. Imperial system:60INCH
Weight range: metric system:90-240CM, it will add or reduce 1CM for each time press. imperial system:22-95INCH, ,it will add or reduce 0.5INCH for each time press.
3)Press "SET" enter into age mode to set up age , press triangle /inverted triangle
button can add/reduce age, it will add or reduce quickly if we keep pressing. Default age:20.Age range:10-19 .
4) Press "SET" enter into step distance mode to set up step distance, press triangle /inverted triangle
button can add/reduce age,it will be add or reduce quickly if we keep pressing.
Default metric system step distance:40CM.Imperial system:40INCH
Step distance:range : metric system:30-180CM, it will add or reduce 1CM for each time press, imperial system:22-95INCH, it will add or reduce 0.5INCH for each time press.
5) Press "SET" again to finish all the settings.
4. To set up the next group data is the same way as above.
Fat analyzer mode :
1.After settings are all done, press "S" (START) button to start the test, in this case, thumbs should place on the left and right touching panel respectively and apply pressure. Result will be shown after 5 seconds.
You can see the body symbol displayed on the lower right corner screen :
1.body type much lighter
2.body type too thin
3.body type standard
4.body type little fat
5.body type much fat
2.When appears ,the fat analyzer tells you there occurs an error information.
See below fat level:
Oriental:
Gender | much lighter
| too thin | standard
| little fat | much fat |
man | 9%↓ | 9%-13.4% | 13.5%-23.9% | 24%-33.9% | 34%↑ |
woman | 9%↓ | 9%-18.9% | 19%-28.9% | 29%-33.9% | 34%↑ |
Westerner:
Gender | much lighter
| too thin | standard
| little fat | much fat |
man | 10%↓ | 10%-14.4% | 14.5%-24.9% | 25%-34.9% | 35%↑ |
woman | 10%↓ | 10%-19.9% | 20%-29.9% | 30%-34.9% | 35%↑ |
Step count mode :
1.Press M(MODE)button to enter step count mode. Press "SET" button for 3-5 seconds to reset the existing records. Tie the pedometer to the belt and keep it horizontally. The system will count the steps and distance you walked and caloried burned according to the settings you have done.
Step counter range :0-9999
Calorie range:0-99999 KCAL
Distance range :0-99999KM/MILE
Press triangle /inverted triangle
button to view your data like step number, calories burned and distance walked.
Press "SET" for 2S to clear the records.
Remark:
1.Please replace the battery if the screen display is not very clear.
2. The results will be influenced if not wear in a proper way.
3. This is an electronic products, It is strictly prohibited to water or liquid into it.
4.Please avoid high temperature and high pressure circumstance.
5.Please avoid high drop and detach pedometer .