F8-s Patient Monitor with Acoustic and Visual Alarm
Negotiable /Set
Min.Order:1 Set
Wanrooe Machinery Co., Ltd. (Zhangjiagang)
F8-s Patient Monitor with Acoustic and Visual Alarm
Features:
1. 12.1' color TFT LED screen
2. Acoustic and visual alarm
3. Display mode: standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG
4. Drug calculation and titration table
5. Suitable for monitoring adult, pediatric and neonatal patient.
6. Real time ST segment analysis, pacemaker detection and Arrhythmia analysis
7. Supporting storage of 240 hours patient data, 1024 NIBP records and 1024 alarm event
8. Isolated against defibrillation effect
Standard Configuration:
3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP
Optional Configuration:
Touch screen, Printer, Trolley, Wall-mount
Dimension and weight | Dimension | 375mm(W)*330mm(H)*180mm(D) |
Weight | standard configuration: 4.4 kg | |
Operation environment | Power requirements | AC 90-300V, 50/60HZ, 60W |
Power | 90VA | |
Temperature | 0-40℃ | |
Humidity | 0-93% non-condensing | |
Safety | Meet the requirements of IEC60601 series | |
Patient range | Adult, neonate and pediatric patients | |
Performance Specification | ||
Display | 12.1 inch (800 x 600 pixel) color TFT LCD rolling and refreshing waveform display | |
Display mode | Standard, large font, trend table, full lead ECG, Oxy CRG,NIBP trend | |
Interface
| Parameter cable interface AC power input socket | |
Battery | Rechargeable battery, 2.2 Ah 12V | |
Alarm indicator | Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm | |
Data storage
| 240 hours monitoring data 1024 NIBP records storage 1024 alarm event | |
Printer
| Built-in 50mm thermal printer (option), 2 traces, print speed 25mm/s & 50mm/s print width:50mm | |
ECG | ||
Leads type | 3(option)/5-lead : I, II, III, aVR, aVL, aVF, V | |
Sweep speed | 12.5mm/s, 25mm/s 50mm/s | |
Gain selection | ×0.25, ×0.5, ×1, ×2 | |
ECG waveform | 1 channels | |
Operation mode | Diagnostic, monitor, surgery | |
Heart rate range | 0 -300bpm | |
Accuracy | 1bpm or ±1% whichever is great | |
Alarm range | Audible and visual alarm, adjustable | |
ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis | |
Protection | Against electrosurgical interference and defibrillation | |
Respiration (RESP) | ||
Method | Thoracic impedance | |
Operation mode | Auto | |
Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | |
Apnea alarm | Yes | |
Alarm | Yes, audible and visual alarm ,alarm events recallable | |
NIBP | ||
Method | Automatic oscillometric | |
Operation mode | Manual/Automatic/STAT |
Auto measure time | Adjustable | |
Measurement unit | mmHg / kPa selectable | |
Test interval | 1-480 minutes | |
Measurement range
| Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg | |
Over-pressure protection | Double safety protection | |
Accuracy of blood pressure measurement | The mean error shall be less than±5mmHg the standard deviation shall be less than 8mmHG | |
Resolution | 1 mmHg | |
SPO2 | ||
Measurement range | 0%-100% | |
Resolution | 1% | |
Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified | |
Alarm range | 1-100% | |
Pulse rate | Pulse range: | 20-300bpm |
Accuracy: | ±3bpm(non-motion) ±5bpm(motion ) | |
Temperature (TEMP) | ||
TEMP range | 0-50℃ | |
Resolution | 0.1 ℃ | |
Accuracy | ±0.1℃ (excluding the sensor) | |
Channel | Single channel. |