F15 Portable Patient Monitor with Multi-Language
USD $500 - $1,000 /Set
Min.Order:1 Set
Wanrooe Machinery Co., Ltd. (Zhangjiagang)
F15 Portable Patient Monitor with Multi-Language
Features:
1. 15' color TFT LCD screen supports display max. 11 waveforms
2. Personated voice reminding alarm; Visual On-display and integrated alarm light
3. Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG.
4. Drug calculation and titration table
5. Real time ST segment analysis, pace maker detection and Arrhythmia analysis,
6. Extended advance function: IBP, IOC, EtCO2, Multi-gas/O2
7. Suitable for monitoring adult, pediatric and neonatal patient.
8. Supporting storage of 720 hours patient data, 1000 NIBP records and 500 alarm event.
9. Internal lead-acid battery
10. Multi-language: Chinese, English, Spanish, Portuguese, Russian, French, German, Czech,
11. Denish, Dutch, Finland, Italian, Porlish, Turkish
Standard Configuration:
1. Anti-glare big screen, rechargeable lead-acid battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional Configuration:
1. 2IBP, Nellcor SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream/ Micro-stream CO2), Multi-Gas/ O2, Pitch Tone
2. VGA, Thermal printer (50 mm)
3. Roller stand with locking castors and intergrades castors
4. Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & SpO2probe
Physical Specifications | |||||
Dimension and weight | Dimension | 330mm(W)*260mm(H)*140mm(D) | |||
Weight | standard configuration: 4 kg | ||||
Operation environment | Power requirements | AC 90-300V, 50/60HZ, 60W | |||
Power | 90VA | ||||
Temperature | 0-40℃ | ||||
Humidity | 0-93% non-condensing | ||||
Safety | Meet the requirements of IEC60601 series | ||||
Patient range | Adult, neonate and pediatric patients | ||||
Performance Specification | |||||
Display | 15’ color TFT LCD screen, support external VGA(option). rolling and refreshing waveform display | ||||
Display mode | Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG. | ||||
Interface
| Parameter cable interface AC power input socket Network interface External VGA interface for connection of alternate display | ||||
Battery | 1 internal rechargeable lead-acid battery, 2.0Ah 12V | ||||
Alarm indicator | Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm | ||||
Data storage
| 720 hours monitoring data 10000NIBP records storage 500 alarm event. | ||||
Printer
| Built-in 50mm thermal printer (option), 3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s print width:50mm | ||||
Net working | Support connection to central monitoring station through LAN (TCP/IP) or wireless connection | ||||
ECG | |||||
Leads type | 3/5-lead : I, II, III, aVR, aVL, aVF, V | ||||
Sweep speed | 12.5mm/s, 25mm/s,50mm/s | ||||
Gain selection | ×0.25,×0.5, ×1, ×2 | ||||
ECG waveform | 3 channels | ||||
Operation mode | Diagnostic, monitor, surgery | ||||
Heart rate range | 15 -350bpm | ||||
Accuracy | 1bpm or ±1% whichever is great | ||||
Alarm range | Audible and visual alarm, adjustable | ||||
ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis | ||||
Protection | Against electrosurgical interference and defibrillation | ||||
Respiration (RESP) | |||||
Method | Thoracic impedance | ||||
Operation mode | Auto/manual | ||||
Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | ||||
Apnea alarm | Yes | ||||
Alarm | Yes, audible and visual alarm ,alarm events recallable | ||||
NIBP | |||||
Method | Automatic oscillometric | ||||
Operation mode | Manual/Automatic/STAT | ||||
Auto measure time | Adjustable | ||||
Measurement unit | mmHg / kPa selectable | ||||
Test interval | 1-480 minutes | ||||
Measurement range
| Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg | ||||
Over-pressure protection | Double safety protection | ||||
Accuracy of blood pressure measurement | The mean error shall be less than±5mmHg the standard deviation shall be less than 8mmHG | ||||
Resolution | 1 mmHg | ||||
SpO2 | |||||
Measurement range | 0%-100% | ||||
Resolution | 1% | ||||
Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified | ||||
Alarm range | 1-100% | ||||
Pulse rate | Pulse range: | 0-350bpm | |||
Accuracy: | ±3bpm(non-motion) ±5bpm(motion ) | ||||
Temperature (TEMP) | |||||
TEMP range | 0-50℃ | ||||
Resolution | 0.1 ℃ | ||||
Accuracy | ±0.1℃ (excluding the sensor) | ||||
Channel | Dual-channel. provide T1;T2; T | ||||
IBP | |||||
Measurement range | -50-360mmHg | ||||
Channel | 2 channels | ||||
Pressure transducer | Sensitive :5u V/V mmHg Impedance range :300-3000 Ω | ||||
Pressure names | ART,PA,CVP,RAP,LAP,ICP,P1,P2 | ||||
Alarm range | -10-300 mmHg | ||||
PR from IBP | Range & Accuracy: | 25-200bpm ±1bpm or ±1bpm which is greater 201-350bpm ±2% | |||
Resolution : | 1bpm | ||||
Depth of Anesthesia (BIS) | |||||
EEG sensitivity | +/- 475μV | ||||
Noise | < 2uVp-p (1-150 Hz) | ||||
CMRR | > 100 dB | ||||
Input impedance | > 50mohm | ||||
Sample rate | 1024 samples/s, 16 bits |
Index and display update | 0-100, filter 1-47 Hz, 1 sec. display update |
EEG waveform | ± 500 µV scaleable, filter 1–30 Hz, 3 sec. window length. |
ESR | 0-100% |
EMG 0-100 arbitrary unit | Curve and bar |
Index trend | 5 min and 60 min |
Digital output | Wireless BT interface (RFCOMM). 10 meters range |
Alarms | IoC high and low user selectable limits |
Artifact rejection | Automatic: user can disable. |
Sensor impedance range | 0 - 14kohm |
EtCO2 (Main-stream / Side-stream / Micro-stream CO2) | |
Measurement range | 0-150mmHg |
Accuracy | ±2mmHg(0-40mmHg) ±5% of reading(41-76mmHg) ±10% of reading (77-99mmHg) |
Resolution | 1mmHg |
Sampling rate | 70m1/min 100m1/min |
Sampling rate accuracy | 0.15 or 15m1/min |
Start-up time
| 30 Sec. the module enters the warming up status after the start up. 1 minute later, it enters the ready-to-measure status. |
Respiration rate | 3-150 rpm |
Respiration rate accuracy | ±2BrPM (0-70BrPM) ±5BrPM (>70BrPM) |
Response time
| When measured with a neonatal water trap and a 2.5 m-long neonatal sampling line: < 3s @ 100 ml/min <4 s @ 70 ml/min |
When measured with an adult water trap and a 2.5 m-long adult sampling line: <5.5 s @ 100 ml/min <7 s @ 70 ml/min | |
Delay time
| When measured with a neonatal water trap and a 2.5m-long neonatal sampling line: <3 s @ 100 ml/min <3.5 s @ 70 ml/min |
When measured with an adult water trap and a 2.5m-long adult sampling line: <5 s @ 100 ml/min <6.5 s @ 70 ml/min | |
Multi-Gas/O2 | |
Method | Infrared absorption |
Gas sorts | CO2, N2 CO2, N2O, Des, Iso, Enf, Sev, Hal, O2, (Optional paramagnetic sensor) |
Measurement range
| CO2: 0~30% N2O : 0~105% O2, :0~105% Enf, Iso, Hal: 0~30% Sev: 0~30% Des:0~30% |
Data output | Fi and ET values |
Respiration rate
| ±1BrPM(2~60BrPM) 61~100BrPM (unspecified) |
Other
| Up to 4 waveforms displayed Agent mixture detection MAC value displayed |