digital target flowmeter, digital flowmeter
USD $244 - $326 /Piece
Min.Order:1 Piece
Xi'an Yunyi Instrument Co., Ltd.
digital target flowmeter, digital flowmeter
1. Introduction
LE1 digital target Flowmeter adopted the newest capacitive force transducer as measurement and sensitive transform element. As well as applied in the newest digital technology and micro electronic technique. So it is a Intelligent Flowmeter, which apply for measuring liquid and gas with high viscosity, low Reynolds number and contains small molecule. So this capacitive force transducer is the key that produced high accuracy and high reliability.
Target Flowmeter is not only have both the characteristics of no moving parts of traditional orifice and vortex Flowmeter, but also have the high accuracy. Combined with its unique anti-interference, impurity resistance, it can application in difficult working condition of the high viscosity/easy to mountains/high temperature/high pressure/high corrosive, etc. at present it has been widely used in steel, oil, natural gas, electric power, papermaking, chemical, energy, food, environmental protection and other fields of flow measurement.
2. scope of application
2.1 it is sutible for all kinds nominal diamters. From DN15~DN2000mm or more than.
1.2 It is apply for high or low temperature meduim: from -50℃~+260℃
2.3 Sutible for low/medium/high pressure: 0~42MPa(gauge pressure)
3. characteristics
3.1 no moving parts, sealing surface to reduce, Greatly reduce the leakage rate, easy installation
and maintenance.
3.2 Wildely measurement range, the maximum measurement range is 20:1(liquid)or 10:1(gas).
3.3 Accurate measurement and high precision, the flanged type precision is 0.2%(liquid) or
0.5%(gas).
3.4 High sensitively, to measure small flow, the measured low flow speed is 0.08m/s, then the electromagnetic Flowmeter is 0.5m/s.
3.5 Good repeatability, 0.05~0.08%, With optional small signal removal, no liner-revision.
3.6 Low pressure loss.
3.7 Easy to calibration, in addition to the standard device, also can adopt dry calibration.
3.8 Low consumption battery display, can read on live.
4. target flowmeter selection table
LE1 | Target Flowmeter | |||||||
Nominal diameter (mm) | 10 | DN10 | ||||||
20 | DN20 | |||||||
… | … | |||||||
2000 | DN2000 | |||||||
Installed mode | D | Clamped-on type with flange | ||||||
F | Flange connection type | |||||||
J | insertion | |||||||
K | The insertion type can tear open or install on live | |||||||
L | Tube taper thread connections | |||||||
Medium | Y | Liquid | ||||||
Q | Gas | |||||||
Z | Liquid | |||||||
Working condition | P | Operating pressure (MPa) | ||||||
T | Operating temperature(℃) | |||||||
v | Medium viscosity (Pa·s) | |||||||
Table body material | T | Carbon steel | ||||||
B | Steel stainless | |||||||
F | Stainless steel lining four fluorine | |||||||
Output signal | L | 4~20mA two-wire system | ||||||
R | RS485 communication protocol | |||||||
H | Frequency signal | |||||||
Explosive requirements | B | Exd II BT4 |