oem service pressure transmitter Eja110a
USD $450 - $800 /Unit
Min.Order:1 Unit
Xi'an Yunyi Instrument Co., Ltd.
oem service pressure transmitter Eja110a
DESCRIPTION of Eja110a pressure transmitter:
The high performance differential pressure transmitter model EJA110A
can be used to measure liquid, gas, or steam flow as well as liquid level,
density and pressure. It outputs a 4 to 20 mA DC signal corresponding
to the measured differential pressure.
The EJASeries is available with BRAIN, HART, FOUNDATION
fieldbus or PROFIBUS PAcommunication protocols.
FEATURES of Eja110a pressure transmitter:
Excellent performance and stability:
The EJA series uses a formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or
temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus
offers unmatched long-term stability.
Compact and light-weight design:
Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell
structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
Fieldbus communication capability:
Fieldbus is a digital twoway communication system. It is a revolutionary technology for configuring instrumentation
control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field
instruments today.
TECHNICAL DATA o Eja110a pressure transmitter:
EJA110A Differential Pressure Transmitter | |||||
| L Capsule | M Capsule | H Capsule | V Capsule | |
Range | -10 to 10 kPa | -100 to 100 kPa | -500 to 500 kPa | -0.5 to 14 MPa | |
| (-40 to 40 inH2O) | (-400 to 400 inH2O) | (-2000 to 2000 inH2O) | (-70 to 2000 psi) | |
Span | 0.5 to 10 kPa | 1 to 100 kPa | 5 to 500 kPa | 0.14 to 14 MPa | |
| (2 to 40 inH2O) | (4 to 400 inH2O) | (20 to 2000 inH2O) | (20 to 2000 psi) | |
Accuracy | ±0.075% | ±0.065% | ±0.065% | ±0.065% | |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | ||||
Certificates | FM, CENELEC ATEX, CSA, IECEx | ||||
Output | 4 to 20 mA DC, FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication | ||||
Supply voltage | BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) | ||||
| Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) | ||||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) | ||||
| -30 to 80 deg C (-22 to 176 deg F) (with integral indicator) | ||||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | ||||
Maximum working pressure | 16MPa(2300psi) | ||||
| 3.5MPa(500psi) for L capsule with special materials | ||||
Mounting | 2-inch pipe mounting | ||||
Wetted parts material | Capsule | SUS316L(Diaphragm material is Hastelloy C-276), | |||
|
| Hastelloy C-276, Tantalum, Monel | |||
| Cover flange | SUS316, Hastelloy C-276, Monel | |||
Housing | Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |