Jumper hot sale vital sign Patient monitor jpd-800B multi parameter patient monitor
Jumper hot sale vital sign Patient monitor jpd-800B multi parameter patient monitor

Jumper hot sale vital sign Patient monitor jpd-800B multi parameter patient monitor

Negotiable /Unit

Min.Order:1 Unit

Supply Ability:
500 Unit / Units per Month
Port:
Shenzhen
Payment Terms:
Credit Card PayPal

Quick Details View All >

Type:
First-Aid Devices
Brand Name:
Jumper
Model Number:
JPD-800B-a
Place of Origin:
Guangdong, China

Shenzhen Jumper Medical Equipment Co., Ltd.

Business Type: Manufacturer
Shenzhen Guangdong China
Main Products: Fetal Doppler ,Fetal Monitor ,Pulse oximeter ,Blood pressure monitor ,Patient monitor

Product Details

12inch Veterinary monitor--suitable for many kinds of animals

Features:

 12" color TFT display, up to 12 waveforms
One level menu, easy to use
Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional)
Maximum 720 hour graphic and tabular trends of all parameters
Built-in recorder and battery
Suitable for dog,cat, horse ,bird etc

Arrhythmia analysis, ST calculation, Pace analysis
Anti-ESU, anti- defibrillator
Standard network interface, can connect to Central monitor system
Optinal: recorder, dual IBP, CO2, IoC

 

 Jumper hot sale vital sign Patient monitor jpd-800B multi parameter patient monitorJumper hot sale vital sign Patient monitor jpd-800B multi parameter patient monitorJumper hot sale vital sign Patient monitor jpd-800B multi parameter patient monitor

Specifications

 

 ECG

Lead mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V,
Waveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain: X2.5mm/mV, X5.0mm/mV, X10mm/mV, X20mm/mV, auto
Resolution 1 bpm
Sensitivity > 200 (uV P-P)
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential 300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range: 8 m V ( Vp-p )
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
5%±Calibration Signal 1 (mV p-p), Accuracy :
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting

 

Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R
ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Available
Review Available


RESPARATION
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 ~ 2.5 KΩ
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range Adult 0 ~ 120 rpm
Neo/Ped 0 ~ 150 rpm
Resolution 1 rpm
Accuracy  2 rpm
Apean Alarm 10 ~ 40 S


NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STATMode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg

MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg

  

Accuracy
Pressure
Maximum Mean error  5mmHg
Maximum Standard deviation  8mmHg
Overpressure Protection
Adult Mode 297 3 mmHg
Pediatric Mode 240 3 mmHg
Neonatal Mode 147 3 mmHg

 

SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy
70% ~ 100%  2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution 1bpm
Accuracy    2bpm


TEMPERATURE
Channel 1
Measuring and Alarm Range 0 ~ 50 C
Resolution 0.1 C
Accuracy  0.1 C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.

 
IBP(Optional)
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP -10 ~ 40 mmHg
P1/P2 -10 ~ 300 mmHg

Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω

 

 

Resolution 1 mmHg
Accuracy 2% or 1mmHg, which great
Actualization interval about 1 Sec.

  

ETCO2(Optional)
Measure range: 0% - 13%
Resolution: 1 mmHg
Accuracy : ±2 mmHg (< 5.0% Measurement Value)
±10%( > 5% Measurement Value)
Response Time: 180ms

 

  

Contact Supplier

Ms. cherry huang Overseas Sales Manag Chat Now
Telephone
86-755-26696279-811
Mobile
18938093602
Fax
86-755-26852025
Address
7th to 10th FL.,East district ,No.71-4, Building D,Xintian Avenue,Fuyong street ,Baoan district ,Shenzhen,China Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Emergency & Clinics Apparatus
Categories
Hi~