Features
- 13 type Arrhythmic Analysis, Multi-lead ECG Waveforms Display in phase, real time ST segment analysis, pacemaker detection drug calculation and titrationable.
- Efficient resistance to interference of defibrillator and electrosurgical cautery.
- SPO2 can testing for 0.1% weak.
- RA-LL impedance respiration.
- Trend coexist displat.
- OxyCRG DyNnamic view display.
- Bed to bed view display.
- Networking capacity and nurse-calling system.
- Up to 4 hours working capacity of built-in rechargeable battery.
- 12.1 inch high resolution color TFT LED display.
- Large volume of tabular and graphic trends information storage and easy to recall.
- Anti-ESU, anti-defibrillator.
- Capture dynamic waveforms.
- Can be used for animals.
- Recorder,IBP(single or double), VGA and ETCO2, Touch Screen for options.
Packaging & Shipping
- Package: 9KG/Carton 1PCS/Carton
- Port: Shenzhen/HK
- Delivery time: 7 working days after receipt of payment
- Payment terms: T/T, Western Union, Paypal
Specification
- ECG
Lead mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
LWaveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain: X2.5mm/mV, X5.0mm/mV, X10mm/mV, X20mm/mV, auto
Resolution 1 bpm
Sensitivity > 200 (uV P-P)
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential 300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range: 8 m V ( Vp-p )
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
5%±Calibration Signal 1 (mV p-p), Accuracy :
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting - RESPARATION
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 ~ 2.5 KΩ
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range Adult 0 ~ 120 rpm
Neo/Ped 0 ~ 150 rpm
Resolution 1 rpm,Accuracy 2 rpm
Apean Alarm 10 ~ 40 S
NIBP
MEAN 20 ~ 235 mmHg
- Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg - SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy
70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution 1bpm
Accuracy 2bpm - TEMPERATURE
Channel 1
Measuring and Alarm Range 0 ~ 50 C
Resolution 0.1 C
Accuracy 0.1 C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec. - IBP(Optional)
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP -10 ~ 40 mmHg
P1/P2 -10 ~ 300 mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1 mmHg
Accuracy 2% or 1mmHg, which great
Actualization interval about 1 Sec. - ETCO2(Optional)
Measure range: 0% - 13%
Resolution: 1 mmHg
Accuracy : ±2 mmHg (< 5.0% Measurement Value)±10%( > 5% Measurement Value)
Response Time: 180ms
Company Information
- Established in 1998, Jumper Medical is dedicated to designing and manufacturing healthcare product for personal and hospital market.
- Our vision is to improve the quality of human life by supplying affordable, convenient and reliable healthcare products to more families around the world.
- Our products include fetal doppler, pulse oximeter, infrared thermometer, blood pressure monitor, fetal monitor/CTG machine,patient monitor, vital signs, multi parameter patient monitor, bed side monitor, ECG machine, etc.Our product are ISO13485, CE, FDA proved. In order to make sure every product conforms to ROHS requirements, all raw materials used are compliant with ROHS directives and all product are produced with ROHS compliance awareness.
- With 15 years' experience in OEM/ODM service and concentration on healthcare industry, Jumper Medical welcomes professional partners to join us to achieve a better future in healthcare community.
FAQ
- Are you a factory or a trade company?
Jumper is a manufacturer in China. With over 15 years experience in medical producing.
- What certificates you have?
We have CE, ISO for all products, FDA for Angelsounds fetal doppler and medical thermometer.
- When will you daspatch teh goods?
We will daspatch the goods within 7 working days after receive your payment.
We accept 100% T/T in advance, Western Union etc.Both USD and RMB are Ok.
- What should I do if goods with defects?
Contact us immediately and collect evidence. We would repair, resend or refund for you.
- What can you offer besides Angelsounds?
We have medical thermometer, pulse oximeter, BP monitor, fetal monitor, patient monitor, ECG machine and so on.