Clenbuterol residue rapid test kit

Clenbuterol residue rapid test kit

USD $10 - $20 /Box

Min.Order:2 Boxes

Supply Ability:
50000 Box / Boxes per Month
Port:
Shanghai
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Shanghai, China
Brand Name:
Quicking
Model Number:
W81102-2
Power:
Hydraulic
Usage:
Other, diagnostic

Quicking Biotech Co., Ltd.

Business Type: Manufacturer,Trading Company
Shanghai China
Main Products: veterinary rapid test kit ,food safety rapid test kit ,ELISA kit

Product Details

Specifications

Clenbuterol residue rapid test kit
Sample: urine,meat,feed
Cut-off: 3 ,5,8ppb
Assay Time: 5 -10 min

1INTENDED USE

Quicking Clenbuterol Rapid Test is a competitive immunoassay for the semi-quantitative detection of the presence of Clenbuterol residue in animals tissue

Cut-off:   1,3 ,5ppb

Assay Time:  5 -10 min

Sample: Tissue

 

2. PRINCIPLE OF THE ASSAY 

Quicking Clenbuterol Rapid Test is based on competitive lateral flow immunochromatographic assay. 

 

3. TEST PROCEDURE

3.1Collect tissue as sample. Get rid of the fat tissue. Homogenize the sample at 10000 rpm for 1 min. Weigh out 4.0 g of sample into a 15 mL centrifugal tube. Add 0.5 mL of assay diluent and tightly cover the lid. 

3.2  Put the tube into a water bath (80°C ) for 10 min. Take out as much the extracted liquid into a 1.5 mL centrifugal tube.

3.3 Do centrifugation at 4000 rpm for 1 min to make the extract clear. NOTE: If there is fat layer, just insert the pipette through the fat layer and take the water phase liquid for running the assay.  

3.4 Take out the cassette from the foil pouch and place it horizontally.

3.5 Gradually drip 3 drops of sample extraction into the sample hole “S”.

3.6 Interpret the result in 5 - 10 min. Result after 10 min is considered as invalid.

 

4. INTERPRETATION OF RESULTS

PositiveOnly one clear band in zone indicates a positive result. Positive shows that the concentration of Clenbuterol is at or above 1,3,5 ppin the sample.

Negative: The presence of both clear band in zone and zone. 

Invalid: No colored band appears in C zone. 

 

 

5. SPECIFICITY

The results are negative when the test is applied to detect 100 ppm of Ractopamine, Trenbolone-acetate, Chloramphenicol, Aminoglycosides, Beta-Lactams, Macrolides, Quinolones, and Sulfonamides.

The results is negative when the test is applied to detect 1 ppm of Salbutamol.      .

 

6. STORAGE

The kit can be stored at room temperature (2-30°C). The test kit is stable through the expiration date (18 months) marked on the foil pouchDO NOT FREEZE. Do not store the test kit in direct sunlight.

 

Contact Supplier

Ms. Vivi Liu Export manager Chat Now
Telephone
86-21-50947188 - 863
Fax
86-21-50947186
Address
No.901 RenYi Village,XinChang Town,PuDong New District,Shanghai 201314,China Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~