Multiparameter Patient Monitor
USD $750 - $950 /Unit
Min.Order:1 Unit
Cmics Medical Instrument Co., Ltd.
As a leading professional manufacturer of ECG machines, Holter Systems, Patient Monitors, Vital sign Monitors, Pulse Oximeters and Fetal Dopples, we have multiple options of 1/3/6/12 channel ECG machines, with features & specifications for PM-200A(Portable Multiparameter Patient Monitor) as follows.
Features
* 12.1 inch high brightness colorful TFT LCD
* Simultaneous display of 7 channel waveform by one screen
* Dual NIBP with over pressure protection
* Analysis of real time ST segment and arrhythmia
* Standard configuration: ECG, NIBP, RESP, SPO2, 1-TEMP, PR, drug dose calculation, OXYCRG
* Optional configuration: 12 lead ECG, 2-TEMP, IBP(single/dual channel), ETCO2(side stream/main stgream), built in thermal printer, ICG and CO
* Standard RJ-45 socket to support networking capacity of maximum 66 beds and compatibility with HIS
* Digital SPO2 enables effective examination in case of active patient and low infusion as well interference caused by electrosurgical unit
* Compact and portable design allows uninterrupted operation with its built in rechargeable battery
Specifications
ECG
Lead Mode: 3/5/10 lead
Lead selection: I, II, III, aVR, aVL, aVF, V- // I, II, III // I, II, III, aVR, aVL, aVF, V1~V6
Gain: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Input impedance: ≥5.0 Mohm
CMRR: DIAG ≥85dB, MON ≥105dB, OPS ≥105dB
Frequency response: DIAG 0.05~75Hz, MON 0.5~25Hz, OPS 1~15Hz
HR range: 10~300 bpm
ECG analysis: Standard analysis of ST segment, QT and arrhythmia
Resolution: 1 bpm
Accuracy: ±1% or ±1 bpm, whichever greater
Lead off alarm: Available
Sweep speed:12.5mm/s, 25mm/s, 50mm/s
Alarm range: 10~300 bpm, continuously adjustable between high/low limit
Trend: 168 hour
NIBP
Measurement method: Automatic oscillometry
Operation mode: Single (manual), cycle (automatic), rapdi (continuous)
Measurement time: Selectable
Measurement parameter: Systolic/diagnostic/mean/PR
Measurement range: 0 ~ 300 mmHg for adult, 0 ~ 235 mmHg for pediatric, 0 ~ 135 mmHg for neonate
Cuff pressure range: 0 ~ 280 mmHg
PR range: 40 ~ 240 bpm
Inflation time: Less than 40 second for standard adult cuff
Resolution: 1 mmHg
Interval for cyckled measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes, 2, 4, 8 hours
Alarm: Available
Data recall: 750 groups for recall and display
RESP
Measurement method: Impeance between RA-LL (R-F)
Impedance range: 0.5 ~ 3 ohm
Measurement range: 0 ~ 180 bpm
Precision: ±2 bpm
Gain: x1, x2, x4
Alarm range: 0 ~ 180 bpm, continuously adjsutable between upper limit and lower limit
Scanning speed: 6.25/mms, 12.5mm/s, 25mm/s
Apnea alarm: Available
SPO2
Probe:Dual wave length LED
Measurement range: 0 ~ 100%
PR range: 20 ~ 250 bpm
Resolution: 1%
Alarm range: 0 ~ 100%, continuously adjustable between upper limit and lower limit
TEMP
Measurement Range: 0 ~ 50 ºC
Resolution of display: ±1 mmHg
Precision: ±0.1 ºC
Connection cable: Compatible with YSI-4400
Alarm range: 0 ~ 50 ºC , continuously adjsutable between upper limit and lower limit
IBP (Optional)
Measurement Range: 45 ~ +300 mmHg
Resolution: 1 mmHg
Precision: ±1 mmHg or 4% of the reading, whichever bigger; ±4 mmHg or 5% of the reading, whichever bigger, excluding the error of the energy converter
Sensitivity of transducer: 5uV/V/mmHg, 2%
Impedance of traneducer: 300 ~ 3000 ohm
Insulation resistance: > 5000 Mohm/1000V
Breakdown voltage: >4000v/ac, 50-60Hz
Pressure classification: ART/PA/CVP/LAP/RAP/ICP
ETCO2 (Optional)
Measurement: 0 ~ 100 mmHg
Resolution: 0.1 mmHg (0.01%)
Precision: 0 ~ 40 mmHg, +0.3%; 40 ~ 100 mmHg, +1.0%
Gallery